Turbo Chef Technologies i5 service manual Troubleshooting F2 LOW TMP Cook Temperature Low

Models: i5

1 85
Download 85 pages 17.59 Kb
Page 57
Image 57
40 TROUBLESHOOTING

40 TROUBLESHOOTING

Troubleshooting:

F2: LOW TMP (Cook Temperature Low)

 

 

 

 

 

 

 

Reset and determine

 

 

 

Is the high-limit

 

 

YES

 

 

why it tripped – excess

 

 

thermostat tripped?

 

 

 

 

 

grease buildup, etc.

 

 

 

 

 

 

 

 

 

 

 

 

(Figure 31, page 34)

 

 

 

 

 

 

 

 

 

 

 

 

 

Is wiring from the solid state relay to the

NO

Is either of the heater ele- ments defective? (heaters should have a resistance of 14.4 Ohms)

NO YES

Replace the defective heater. (page A-11)

I/O control board OK? Troubleshooting: NO (See page 51 for

schematic)

YES NO

 

 

 

 

 

 

 

Is the RTD

 

Correct wiring.

functioning properly?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the solid state relay defective?

YES

Replace the solid state relay. (page A-5)

YES NO

Replace the I/O control board (page A-8).

Ensure wiring is correct. If necessary, replace RTD. (page A-11)

Page 57
Image 57
Turbo Chef Technologies i5 service manual Troubleshooting F2 LOW TMP Cook Temperature Low