Fault Code Troubleshooting

From TEST MODE, you can run oven diagnostics and check fault counts. To access TEST MODE or turn on Diagnostic mode, see page 15.

Troubleshooting:

F1: BLOWER (Blower Running Status Bad)

39

Is the wiring harness properly connected?

Check the motor

 

 

Are Status Indicators “B”

 

 

 

 

 

 

 

 

NO

 

 

 

YES

 

 

 

 

 

 

and “T” backlit in TEST

 

 

 

Is each blower motor

 

 

 

 

 

 

 

 

MODE? (see page 15)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

spinning freely?

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

controller, top and bottom blower motors, and I/O control board. (See page 51 for schematic.)

NO

Correct the wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove obstruction or if neces-

 

 

 

 

 

NO

 

 

 

 

 

sary, replace blower motor(s)

 

 

 

 

 

 

 

 

(pages A-9 through A-10).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do resistance measurements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

between windings and chassis

 

 

 

 

 

 

 

agree with values on motor

 

 

 

 

 

 

 

 

 

 

 

windings resistance table?

 

 

 

 

 

 

 

 

 

 

 

(Figure 33, below)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Is output from I/O board to harness 1-10 volts? (Verify at test points).

NO

Replace the I/O board (page A-8).

or replace I/O control board (page A-8)/motor controller (page A-7) if damaged.

 

 

Replace the blower motor(s). Be

Replace motor

 

sure to check both the top and

controller. (page A-7)

 

bottom blower motors (pages A-9

 

 

through A-10).

 

 

 

To

From

Description

Expected Resistance

 

 

 

 

Black

Red

Winding (A-B)

5.9-7.3 Ohms

 

 

 

 

Black

White

Winding (A-C)

5.9-7.3 Ohms

 

 

 

 

Red

White

Winding (B-C)

5.9-7.3 Ohms

 

 

 

 

Black, Red, or White

Green

Windings to Chassis

Open

 

 

 

 

Figure 33: Motor Windings Resistance Table

TROUBLESHOOTING

Page 56
Image 56
Turbo Chef Technologies i5 service manual Fault Code Troubleshooting, Below