Fault Code Troubleshooting
From TEST MODE, you can run oven diagnostics and check fault counts. To access TEST MODE or turn on Diagnostic mode, see page 15.
Troubleshooting:
F1: BLOWER (Blower Running Status Bad)
39
Is the wiring harness properly connected?
Check the motor
|
| Are Status Indicators “B” |
|
|
|
|
|
|
|
| NO |
|
|
| |
YES |
|
|
|
|
| ||
| and “T” backlit in TEST |
|
|
| Is each blower motor | ||
|
|
|
|
|
| ||
|
| MODE? (see page 15) |
|
|
|
| |
|
|
|
|
|
| ||
|
|
|
|
|
| spinning freely? | |
|
|
|
|
|
|
| |
YES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
controller, top and bottom blower motors, and I/O control board. (See page 51 for schematic.)
NO
Correct the wiring
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Remove obstruction or if neces- |
|
|
|
|
| NO | ||||||||
|
|
|
| ||||||||||||
| sary, replace blower motor(s) |
|
|
|
|
|
|
| |||||||
| (pages |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||||
| Do resistance measurements |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| YES | |||||||
|
|
|
|
|
|
|
| ||||||||
| between windings and chassis |
|
|
|
|
|
| ||||||||
| agree with values on motor |
|
|
|
|
|
|
|
|
|
| ||||
| windings resistance table? |
|
|
|
|
|
|
|
|
|
| ||||
| (Figure 33, below) |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| YES |
|
| NO |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
YES
Is output from I/O board to harness
NO
Replace the I/O board (page
or replace I/O control board (page
|
| Replace the blower motor(s). Be |
Replace motor |
| sure to check both the top and |
controller. (page |
| bottom blower motors (pages |
|
| through |
|
|
|
To | From | Description | Expected Resistance |
|
|
|
|
Black | Red | Winding | |
|
|
|
|
Black | White | Winding | |
|
|
|
|
Red | White | Winding | |
|
|
|
|
Black, Red, or White | Green | Windings to Chassis | Open |
|
|
|
|
Figure 33: Motor Windings Resistance Table
TROUBLESHOOTING