Table 2 - General data - RTCA

Unit size

 

108

109

111

113

115

116

Condenser

 

 

 

 

 

 

 

Condenser type

 

 

 

Aluminium fins/copper tubes

 

 

Fin spacing

(fins/ft)

168

168

144

168

168

144

Frontal surface area

(m²)

5.7

6.9

6.9

11.3

11.7

13.7

Airflow

 

 

 

 

 

 

 

Standard unit

(m3/h)

42500

50400

69300

77200

84700

98500

Low noise unit

(m3/h)

34500

40900

56300

62700

68800

80000

Condenser fans

 

 

 

 

 

 

 

Number of fans

 

4

4

6

8

8

12

Fan speed

 

 

 

 

 

 

 

Standard unit

(rpm)

 

 

 

690

 

 

Low noise unit

(rpm)

 

 

 

560

 

 

Nominal fan power

 

 

 

 

 

 

 

Standard unit

(kW)

 

 

 

0.85

 

 

Low noise unit

(kW)

 

 

 

0.54

 

 

Current fan amps

 

 

 

 

 

 

 

Standard unit

(A)

 

 

 

2.4

 

 

Low noise unit

(A)

 

 

 

1.2

 

 

Minimum Starting/

 

 

 

 

 

 

 

Operating Ambient (1)

(°C)

 

 

7 Standard units/-18 Low ambient units

 

 

Refrigerant

 

 

 

 

R134a

 

 

Number of Independent

 

 

 

 

 

 

 

Refrigerant Circuits

 

1

1

1

1

1

1

Refrigerant Charge

(kg)

22

26

36

44

52

72

Operating Weight (2)

(kg)

810

890

1090

1535

1770

2050

Shipping Weight (2)

(kg)

1020

1100

1300

1870

2170

2450

Hot gas connection

(inches)

1 5/8

1 5/8

1 5/8

1 5/8

1 5/8

1 5/8

Liquid connection

(inches)

1 1/8

1 1/8

1 1/8

1 1/8

1 1/8

1 1/8

Unit size

 

208

209

211

213

215

216

Condenser

 

 

 

 

 

 

 

Condenser type

 

 

 

Aluminium fins/copper tubes

 

 

Fin spacing

(fins/ft)

168

168

144

168

168

144

Frontal surface area

(m²)

5.7

6.9

6.9

11.3

11.7

13.7

Airflow

 

 

 

 

 

 

 

Standard unit

(m3/h)

42500

50400

69300

77200

84700

98500

Low noise unit

(m3/h)

34500

40900

56300

62700

68800

80000

Condenser fans

 

 

 

 

 

 

 

Number of fans

 

2 x 2

2 x 2

2 x 3

2 x 4

2 x 4

2 x 6

Fan speed

 

 

 

 

 

 

 

Standard unit

(rpm)

 

 

 

690

 

 

Low noise unit

(rpm)

 

 

 

560

 

 

Nominal fan power

 

 

 

 

 

 

 

Standard unit

(kW)

 

 

 

0.85

 

 

Low noise unit

(kW)

 

 

 

0.54

 

 

Current fan amps

 

 

 

 

 

 

 

Standard unit

 

 

 

 

2.4

 

 

Low noise unit

 

 

 

 

1.2

 

 

Minimum Starting/

 

 

 

 

 

 

 

Operating Ambient (1)

(°C)

 

 

7 Standard units/-18 Low ambient units

 

 

Refrigerant

 

 

 

 

R134a

 

 

Number of Independent

 

 

 

 

 

 

 

Refrigerant Circuits

 

2

2

2

2

2

2

Refrigerant Charge

(kg)

2 x 11

2 x 13

2 x 18

2 x 22

2 x 26

2 x 36

Operating Weight (2)

(kg)

810

890

1090

1535

1770

2050

Shipping Weight (2)

(kg)

1020

1100

1300

1870

2170

2450

Hot gas connection

(inches)

1 5/8

1 5/8

1 5/8

1 5/8

1 5/8

1 5/8

Liquid connection

(inches)

1 1/8

1 1/8

1 1/8

1 1/8

1 1/8

1 1/8

(1)Based on a 2.2 m/s wind across the condenser