Trane TSC060-120 manual Model Number Description

Models: TSC060-120

1 48
Download 48 pages 56.85 Kb
Page 12
Image 12
Model

Model

Number

Description

T 1

S

C

060

A

D

R

O

A ** C

0

0

0

0

0

0

0

0

0

0

1

2

3

4,5,6

7

8

9

10

11 12,13 14

15

16

17

18

19

20

21

22

23

24

25

Digit 1 - Unit Function

T = DX Cooling

Digit 2 - Efficiency

S = Standard Efficiency

Digit 3 - Airflow

C = Convertible

Digits 4,5,6 - Nominal Gross Cooling Capacity (MBh)

 

 

kW

Tons

060

= 17.6

5

072

= 21.1

6

090

=

26.4

7.5

102

=

29.9

8.5

120

= 35.1

10

Digit 7 - Major Design Sequence

A = First

Digit 8 - Unit Voltage

D = 380-415/50/3

Digit 9 - Unit Controls

R = ReliaTelMicroprocessor

Digit 10 - Heating Capacity

0 = No Electric Heat

Digit 11 - Minor Design Sequence

A = First Sequence

Digits 12, 13 - Service Sequence

**= Factory Assigned

Digit 14 - Fresh Air Selection

0 = No Fresh Air

A = Manual Outside Air Damper 0-50%

B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100%

without Barometric Relief

D = Economizer, Dry Bulb 0-100% with Barometric Relief

E = Economizer, Reference Enthalpy 0-100% without Barometric Relief F = Economizer, Reference Enthalpy

0-100% with Barometric Relief

G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief

H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief

Digit 15 - Supply Fan/Drive Type/Motor

0 = Standard Drive

1 = Oversized Motor

Digit 16 - Hinged Service Access/Filters

0 = Standard Panels/Standard Filters

A = Hinged Access Panels/Standard Filters

B = Standard Panels/

50 mm (2”) Pleated Filters

C = Hinged Access Panels/

50 mm (2”) Pleated Filters

Digit 17 - Condenser Coil Protection

0 = Standard Coil

1= Standard Coil with Hail Guard

2= Epoxy Coated Condenser Coil

3= Epoxy Coated Condenser Coil with Hail Guard

Digit 18 - Through the Base Provisions

0 = No Through the Base Provisions

Digit 19 - Disconnect/Circuit Breaker/Phase Monitor (3 phase only)

0 = No Disconnect or Circuit Breaker

3 = Phase Monitor Only (No Disconnect, No Circuit Breaker)

Digit 20 - Convenience Outlet

0 = No Convenience Outlet

Digit 21 - Communications Options

0 = No Communications Interface

1 = Comm-3/4 Communications Interface

2 = Comm-5 Communications Interface

Digit 22 - Refrigeration System Option

0 = Standard Refrigeration System

Digit 23 - Refrigeration Controls

0 = No Refrigeration Control

Digit 24 - Smoke Detector

0 = No Smoke Detector

Digit 25 - Monitoring Controls

0 = No Monitoring Control

1= Clogged Filter Switch

2= Fan Failure Switch

3= Discharge Air Sensing Tube

4= Clogged Filter Switch and Fan Fail Switch

5= Clogged Filter Switch and Discharge Air Sensing Tube

6= Fan Fail Switch and Discharge Air Sensing Tube

7= Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube

12