Performance

Data

Table PD-21 — Static Pressure Drops Through Accessories - (Pascals)

 

 

 

 

 

Economizer

 

 

 

Electric Heater

 

Unit

Airflow

Standard

Pleated Filters

 

OA/RA Dampers2

 

 

 

Accessory (kW)3

 

 

 

 

 

 

100% OA

100% RA

100% OA

100% RA

 

 

 

 

 

 

 

 

Model No.

(m3/h)

Filters1

(50 mm)

Downflow

Horizontal

9

13-27

40

TSC060AD

2720

25

37

30

11

30

4

11

13

-

 

3400

37

55

46

17

46

6

17

21

-

 

4080

55

72

64

26

64

9

25

30

-

TSC072AD

3260

10

17

25

2

15

5

-

5

-

 

4080

15

22

27

5

20

5

-

8

-

 

4890

22

30

33

10

25

10

-

13

-

TSC090AD

4080

15

22

27

5

20

5

-

8

-

 

5100

25

32

35

12

30

12

-

16

-

 

6120

35

45

52

17

62

20

-

25

-

TSC102AD

4620

12

20

31

7

22

10

-

6

-

 

5780

20

27

47

15

45

15

-

10

-

 

6930

30

40

75

17

77

22

-

15

-

TSC120AD

5440

17

25

42

12

35

12

-

9

10

 

6800

27

37

65

17

75

20

-

14

17

 

8160

40

50

85

22

87

25

-

20

26

Notes:

1.Tested with standard filters. The TSC060AD has 25 mm (1 inch) standard fiters. The TSC072AD - 120AD has 50 mm (2 inch) standard filters. The difference in pressure drop should be considered when utilizing optional 50 mm (2 inch) pleated filters.

2.OA = Outside Air and RA = Return Air

3.Nominal kW ratings at 415 V

Table PD-21a — Static Pressure Drops Through Accessories - (Inches of Water Column)

 

 

 

 

 

Economizer

 

 

 

Electric Heater

 

 

 

 

 

 

OA/RA Dampers2

 

 

 

Accessory (kW)3

 

Unit

Airflow

Standard

Pleated Filters

100% OA

100% RA

100% OA

100% RA

 

 

 

 

 

 

 

 

Model No.

(CFM)

Filters1

(2 inch)

Downflow

Horizontal

9

13-27

40

TSC060AD

1600

0.10

0.15

0.12

0.04

0.12

0.01

0.045

0.053

-

 

2000

0.15

0.22

0.18

0.07

0.18

0.02

0.070

0.083

-

 

2400

0.22

0.29

0.26

0.10

0.26

0.04

0.100

0.120

-

TSC072AD

1920

0.04

0.07

0.10

0.01

0.06

0.02

-

0.021

-

 

2400

0.06

0.09

0.11

0.02

0.08

0.02

-

0.034

-

 

2880

0.09

0.12

0.13

0.04

0.10

0.04

-

0.052

-

TSC090AD

2400

0.06

0.09

0.11

0.02

0.08

0.02

-

0.034

-

 

3000

0.10

0.13

0.14

0.05

0.12

0.05

-

0.063

-

 

3600

0.14

0.18

0.21

0.07

0.25

0.08

-

0.102

-

TSC102AD

2720

0.05

0.08

0.12

0.03

0.09

0.04

-

0.026

-

 

3400

0.08

0.11

0.19

0.06

0.18

0.06

-

0.041

-

 

4080

0.12

0.16

0.30

0.07

0.31

0.09

-

0.059

-

TSC120AD

3200

0.07

0.10

0.17

0.05

0.14

0.05

-

0.036

0.042

 

4000

0.11

0.15

0.26

0.07

0.30

0.08

-

0.056

0.070

 

4800

0.16

0.20

0.34

0.09

0.35

0.10

-

0.081

0.106

Notes:

1.Tested with standard filters. The TSC060AD has 25 mm (1 inch) standard fiters. The TSC072AD - 120AD has 50 mm (2 inch) standard filters. The difference in pressure drop should be considered when utilizing optional 50 mm (2 inch) pleated filters.

2.OA = Outside Air and RA = Return Air

3.Nominal kW ratings at 415 V

Table PD-22 - Electric Heater Voltage Correction Factors (Apply to Auxiliary Electric Heat

Capacity)

Nominal

Distribution

Capacity

Voltage

Voltage

Multipiler

 

380

0.84

415

400

0.93

 

415

1.00

30

RT-PRC016-EN

Page 30
Image 30
Trane TSC060-120 Economizer, Unit Airflow Standard Pleated Filters OA/RA Dampers2, 100% OA 100% RA Model No M3/h, 1600

TSC060-120 specifications

The Trane TSC060-120 is a prominent member of Trane's commercial HVAC (Heating, Ventilation, and Air Conditioning) systems, designed to meet the demands of various applications, from small offices to larger commercial venues. This model is part of Trane’s variable refrigerant flow (VRF) systems, which are known for their energy efficiency and flexibility.

One of the standout features of the TSC060-120 is its capacity range, which allows for cooling and heating capacities between 60,000 to 120,000 BTUs. This makes it suitable for diverse environments, adapting well to fluctuating load requirements. Additionally, the unit is designed with a modular approach, meaning that multiple units can be connected to meet larger capacity needs without sacrificing efficiency.

The Trane TSC060-120 incorporates advanced inverter technology, which helps optimize energy consumption by adjusting the compressor speed based on the real-time thermal load of the building. This results in a significant reduction in energy costs and improved comfort levels for occupants. The unit also features a high-efficiency multi-stage filtration system that not only ensures clean air circulation but also contributes to the overall indoor air quality.

The system utilizes a compact and versatile design, allowing for flexible installation options. Its lightweight structure and smaller footprint make it easier to install in tight spaces while still accommodating a powerful performance. The TSC060-120 is designed for quiet operation, which is crucial for noise-sensitive environments, delivering comfort without disruptive sound levels.

In terms of control and monitoring, the TSC060-120 is compatible with Trane's advanced building management systems. This integration allows facility managers to monitor energy usage, schedule maintenance, and control temperatures remotely, enhancing overall operational efficiency.

Moreover, the unit is built with sustainability in mind, using eco-friendly refrigerants that comply with the latest environmental regulations. This commitment to sustainability not only minimizes the ecological footprint but also positions the Trane TSC060-120 as a forward-thinking choice for businesses looking to enhance their energy strategy.

In summary, the Trane TSC060-120 stands out for its efficiency, flexibility, and advanced technology, making it a solid choice for commercial HVAC applications. With its combination of high performance, advanced control features, and commitment to sustainability, it provides an effective solution for modern climate control needs.