2.2.3Replacing the Management Modules

CPSMC08xx-100 PointSystem™ Chassis

2.2.3Replacing the Management Modules

CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing media converter slide-in-module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the management module(s).

NOTE: The management modules can be replaced while the chassis remains powered. However, you must configure a new IP address for the replacement management module. For more information, see the FocalPoint™ 2.0 user’s guide on the enclosed application CD or on-line at www.transition.com.

To replace a management module in the CPSMC08xx-100 chassis:

1.Remove the management module to be replaced by loosening the panel fastener screw that secures the module to the chassis front. Slide the module from the chassis.

2.Align the replacement module with the installation slot so that the panel fastener screw to the left of the module..

 

 

 

Input Power:

 

 

 

110-240 VAC

 

 

 

1.6A max. (60W max)

 

 

 

50/60 Hz

 

 

RESET

DB-9

PWR

LNK

CPSMC-0800

TX

RX

 

8-Slot Chassis

Panel Fastener Screw

3.Carefully slide the replacement management module into the installation slot, while aligning the module’s circuit board with the installation guides.

NOTE: Ensure that the management module is firmly seated inside the chassis.

4.Push in and rotate the attached panel fastener screw clockwise to secure the management module to the chassis.