4.2Cascade Option

CPSMC08xx-100 PointSystem™ Chassis

4.2Cascade Option

The CPSMM-200 management module is installed in the first chassis in the series

The management module cascade option allows the network administrator to connect up to eight (8) CPSMC08xx-100 chassis into one manageable stack, providing a single management source for up to 55 installed media converter devices.

To create the cascade option, the CPSMM-200 Dual Slot Master Management Module is installed in the first chassis in the series. The CPSMM-210 Single-Slot Expansion Management Module is installed in each subsequent chassis.

 

 

RESET

DB-9

 

 

 

 

PWR

LNK

 

 

 

 

 

Input Power:

TX

RX

 

 

 

 

 

 

110-240 VAC

 

 

 

 

 

 

 

 

1.6A max. (60W max)

 

 

TERM

INIT

12C

12C-1

 

MGMT MASTER

50/60 Hz

 

10BASE-T

INPORT

OUTPORT

MCCM10

CPSMC-0800

 

 

 

 

 

 

 

 

8-Slot Chassis

The CPSMM-210 management module is installed in each subsequent chassis

RESET Pwr

RESET Pwr

RESET Pwr

Input Power:

110-240 VAC

1.6A max. (60W max)

50/60 Hz

CPSMC-0800

8-Slot Chassis

Input Power:

110-240 VAC

1.6A max. (60W max)

50/60 Hz

CPSMC-0800

8-Slot Chassis

Input Power:

110-240 VAC

1.6A max. (60W max)

50/60 Hz

CPSMC-0800

8-Slot Chassis

The CPSMM-200 management module is installed in the first chassis in the series

An alternative setup involves installing two CPSMM-200 Dual-Slot Master Management Modules into two adjacent chassis chassis for redundant management.

 

 

RESET

DB-9

 

 

 

 

PWR

LNK

 

 

 

 

 

Input Power:

TX

RX

 

 

 

 

 

 

110-240 VAC

 

 

 

 

 

 

 

 

1.6A max. (60W max)

 

 

TERM

INIT

12C

12C-1

 

MGMT MASTER

50/60 Hz

 

10BASE-T

INPORT

OUTPORT

MCCM10

CPSMC-0800

 

 

 

 

 

 

 

 

8-Slot Chassis

chassis

Another CPSMM-200 managment module is installed in the next chassis as a backup

 

 

RESET

DB-9

 

 

 

 

PWR

LNK

 

 

 

 

 

Input Power:

TX

RX

 

 

 

 

 

 

110-240 VAC

 

 

 

 

 

 

 

 

1.6A max. (60W max)

 

 

TERM

INIT

12C

12C-1

 

MGMT MASTER

50/60 Hz

 

10BASE-T

INPORT

OUTPORT

MCCM10

CPSMC-0800

 

 

 

 

 

 

 

 

8-Slot Chassis

In this set-up, the two CPSMM-200 management modules auto-negotiate so that one module is in stand-by mode. If the primary management module fails, the stand-by module automatically takes over and manages the network.