33

Wiring Diagram for Magnetic Loop

Black

 

24Vac

 

 

 

White

Close

 

 

Yellow

 

Open

Blue

 

 

Grey Brown

Common

6-8 feet

2-3 feet

Cut one groove and put wires on top of each other starting at the detector. Follow the groove to the rectangle and go around it three times, one on top of the other then back to the detector. You end up with two wires at the detector which go to grey and brown.

Suggested Installation of Magnetic Loop

Concrete Pad

Loop

6-8 feet

Wires to box

Wall

2-3 feet

40 inches

Door

Car Wash Bay

The loop needs to be wire-strapped to wire mesh in the concrete.

Page 35
Image 35
Ultimate Products UP-206 manual Suggested Installation of Magnetic Loop