If you experience difficulty while in TrunkTracker™ mode,
try the following steps.
Problem Suggestion
Scannerwon’t track the trunked
system.
1. May not be a system which can be tracked by
yourscanner.
2. Missing the data frequency.
3. Change to a Type 1 Scanner setup.
ReviewFleet Map Programming on page 56.
Scannerwon’t stop during Scan
Listmode.
1. No IDs have been programmed.
2. The IDs you have stored are not active.
Scannerwill not acquire data
channel.
1. Adjust the squelch for trunking mode.
Seepage 39.
2. Missing the frequency used for the data
channel.Check your frequency list.
Missingreplies to conversations. 1. Change to a Type 1 Scanner setup.
ReviewFleet Map Programming on page 56.
2. Try another Preset Fleet Map or Program
yourown Fleet Map.
3. Check to see that all of the systems
frequencieshave been entered.
ChannelActivity Indicators are
flashingbut no sound is heard.
1. May be a private or telephone
interconnectcall, which are intentionally
blockedby your scanner.
2. The ID in your display is not active.
Scannernot tracking an EDACS
systemproperly.
1. Logical channel numbers ( frequencies)
forthe system are not programmed in the correct
order.Check frequency resources and reprogram.
2. Not all frequencies for the system are
programmed.Check frequency resources.
If you still cannot get satisfactory results while using your
scanner or if you want additional information, please call or
write the Uniden Parts and Service Division. The address
and phone number are listed in the Warranty at the end of
this manual. If you would like immediate assistance, please
call Customer Service at (800) 297-1023.
If you have internet access, you can visit
www.uniden.com or www.trunktracker.com or
www.bearcat1.com/free.htm for additional information.