6.1.2 Bar Code Length Setting:

The following example illustrates how to set Code 39 with a minimum length of 5 and a maximum length of 20:

*Scan “Enter Group 5”.

*Scan “F1” to select Code 39.

*Scan “MIN LENGTH” to enter minimum length setting.

*Scan “0” and “5” to select length 5.

*Scan “MIN LENGTH” to end minimum length setting.

*Scan “MAX LENGTH” to enter maximum length setting.

*Scan “2” and “0” to select length 20.

*Scan “MAX LENGTH” to end maximum length setting.

*Scan “Exit” to end setup.

6.1.3 Code ID Setting:

Each bar code symbology supported by the scanner has a default ID character defined as below: (If you don’t know what is the label that you’re scanning, you may use this feature to identify.)

Symbology

Pre-Defined

UPC-A

A

UPC-E

E

EAN-13

F

EAN-8

FF

I 2 of 5

I

S 2 of 5

H

Code 39

M

Codabar

N

Code 93

L

Code 128

K

UCC/EAN128

]C1

MSI

O

Code 32

T

Delta Code

D

Plessey Code

P

Label Code IV,V

B

China Postal Code

C

Page 16