6.1.2 Bar Code Length Setting:
The following example illustrates how to set Code 39 with a minimum length of 5 and a maximum length of 20:
*Scan “Enter Group 5”.
*Scan “F1” to select Code 39.
*Scan “MIN LENGTH” to enter minimum length setting.
*Scan “0” and “5” to select length 5.
*Scan “MIN LENGTH” to end minimum length setting.
*Scan “MAX LENGTH” to enter maximum length setting.
*Scan “2” and “0” to select length 20.
*Scan “MAX LENGTH” to end maximum length setting.
*Scan “Exit” to end setup.
6.1.3 Code ID Setting:
Each bar code symbology supported by the scanner has a default ID character defined as below: (If you don’t know what is the label that you’re scanning, you may use this feature to identify.)
| Symbology | |
| A | |
| E | |
| F | |
| FF | |
| I 2 of 5 | I | 
| S 2 of 5 | H | 
| Code 39 | M | 
| Codabar | N | 
| Code 93 | L | 
| Code 128 | K | 
| UCC/EAN128 | ]C1 | 
| MSI | O | 
| Code 32 | T | 
| Delta Code | D | 
| Plessey Code | P | 
| Label Code IV,V | B | 
| China Postal Code | C | 