Page D.7
D.7 Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / EAN128
Enter Group 7 Group Default
0
1
2
3
4
5
6
7
8
9
Code 39: 0/1--Disable/Enable.
2/3--Full ASCII/ Standard.
4--Check Digit (CD) Calculate & Send.
5--CD Calculate, not send. 6 --CD not Calculate.
7/8 -- Send/No Send Start/Stop
0 - 48 -- Min length 0 / Max length 48
F1
I 2 of 5 (ITF): 0/1--Disable/Enable
2/3--Fix Length On/Off ( by first three reads)
4--Check Digit (CD) Calculate & Send
5--CD Calculate, not send. 6--CD not Calculate
7--First Digit Suppressed. 8--Last Digit Suppressed
9 -- Not Suppressed
2 - 64 -- Min length 10 / Max length 64
F2
S 2 of 5 / China Postal Code(Toshiba
Code):
0/1--Disable/Enable
2/3 -- Fix Length On/Off ( by first three reads)
4--Check Digit (CD) Calculate & Send
5--CD Calculate, not send. 6--CD not Calculate
1 - 48 -- Min length 4 / Max length 48
F3
Code 32(Italian pharmacy):
0/1 -- Disable/Enable
2/3 -- Leading Character Send / No Send
4/5 -- Tailing Character Send / No Send F4
Reserve
F5
UCC/EAN 128: 0/1—disable/Enable
2/3—Code ID disable/Enable
Note: If EAN128 be disabled, the EAN128 labels will
be decoded as Code 128
F6
Define the EAN128 Fields separator:
Scan a ASCII code in full ASCII code chart
to select a new definition of Func1 F7
Min Length
MM
Max Length
NN Exit