TTL RS232 Interface:

The following table shows pinout for TTL RS232 interface at modular connector:

Pin Number

Signal

1

Not Used

2

VCC(+5V, output)

3

DET

4

GND

5

RXD

6

TXD

7

Power Input (+5V)

8

CTS

9

RTS

10

Not Used

Note:

(1)DET signal is bi-directional I/O pin and for internal use only.

(2)CTS and RXD are input signals and take 0V to 5V only. If the scanner is used to interface with a standard RS232 port, those signals should not be connected.

Standard RS232 Interface:

To support standard RS232 interface, an RS232 adapter cable from the manufacture must be used. This cable is a special one and can not be replaced by the others. One end of that cable which has RS232 signal presented is a DB25 or DB9 female connector and has following pinout:

13

1

25

14

DB25 Female (Front View)

Pin

Signal

Number

 

2

RXD

3

TXD

14

CTS

16

RTS

7

GND

25

Power Input(+5V±5%)