TTL RS232 Interface:
The following table shows pinout for TTL RS232 interface at modular connector:
| Pin Number | Signal | 
| 1 | Not Used | 
| 2 | VCC(+5V, output) | 
| 3 | DET | 
| 4 | GND | 
| 5 | RXD | 
| 6 | TXD | 
| 7 | Power Input (+5V) | 
| 8 | CTS | 
| 9 | RTS | 
| 10 | Not Used | 
Note:
(1)DET signal is 
(2)CTS and RXD are input signals and take 0V to 5V only. If the scanner is used to interface with a standard RS232 port, those signals should not be connected.
Standard RS232 Interface:
To support standard RS232 interface, an RS232 adapter cable from the manufacture must be used. This cable is a special one and can not be replaced by the others. One end of that cable which has RS232 signal presented is a DB25 or DB9 female connector and has following pinout:
| 13 | 1 | 
| 25 | 14 | 
| DB25 Female (Front View) | |
| Pin | Signal | 
| Number | 
 | 
| 2 | RXD | 
| 3 | TXD | 
| 14 | CTS | 
| 16 | RTS | 
| 7 | GND | 
| 25 | Power Input(+5V±5%) | 
Page 30