United States Stove 6039I ERROR CODES and DISPLAY INDICATORS, Err1, Err2, Err3, Err4, Err5, Err6

Models: 6039I

1 32
Download 32 pages 23.58 Kb
Page 23
Image 23
ERROR CODES and DISPLAY INDICATORS

ERROR CODES and DISPLAY INDICATORS

CAUTION: When performing any internal electrical maintenance

Moving parts inside of the cabinet may cause injury. Do not operate unit with panels removed or open.

HOT parts. Do not operate the unit with panel open.

Risk of electric shock. Disconnect power before servicing unit.

In the event of component failure, replace with the original factory equipment.

Error

Error

Possible

Code

Descrption

Causes

Err1

The high limit temperature sensor

Inadequate ventilation.

 

has tripped.

Room fan failure.

 

 

Exhaust Blockage.

 

 

• Electrical Open in the over temperature switch or wiring.

Err2

Stove ran out of fuel during normal

Hopper Empty.

 

operation.

• Auger output failure or jam.

 

 

• Flame of fuel quality caused fire to burn too slowly or go out.

 

 

• Electrical Open in low temperature switch or wiring.

 

 

 

Err3

The stove was unable to reach the Room

• Flame or Fuel quality caused the fire to burn too slowly or go

 

Fan On temperature within the startup

 

out.

 

time.

Auger output failure or jam Hopper empty on startup.

Err4

The power failed while the stove was hot,

• Electrical Open in low temperature switch or wiring.

 

and when power was restored, the fire

Power loss

 

was out.

 

 

Err5

The Auger output fuse has blown.

• Auger motor jammed or bad.

 

 

 

Err6

The Agitator output fuse has blown.

• Agitator motor jammed or bad.

Err7

The Draft Fan (Exhaust Fan) output fuse

• Draft Fan motor jammed or bad.

 

has blown.

 

 

Err8

The Room Fan output fuse has blown.

• Room fan motor jammed or bad.

 

 

 

 

Display Indicators

Several situations or events are indicated in normal operation by blinking display indicators or segments in the display:

Flashing On Indicator: This means that the stove is in the “Start Up” state waiting for either a 3 minute timeout to begin burning or for the stove to reach the warm temperature whichever comes first.

Flashing Off Indicator: This indicates that the stove is in the “Shutdown” state waiting for the OFF button, or for a 15 minute period after the stove was turned off, or for the stove to cool down, or for the door to be closed.

Flashing dash in Heat Range Display: This indicates that the stove is in the normal run mode and is ramping from the current heat range setting to the target heat range setting. Once the ramp is complete, the dash will stop flashing. For ramping from heat range 1 to 9, the default time is 12 minutes (with a 90 second ramp time).

Flashing Automatic Mode Indicator: This indicates that the stove is in normal operation and is running in the automatic mode. However, either the Draft Fan or Auxiliary setting is manually configured.

Flashing Draft Fan Setting Indicator: This indicates that the stove is in normal operation and that the vacuum sensor detects a loss of pressure either because the door is open or because there is a negative pressure in the room with respect to the exhaust.

Factory Defaults

To return the control to its original factory default settings, press and hold the AUX UP and AUX DOWN buttons together for three seconds.