Vanguard Heating SBVBP(C) INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2, Owner’S Manual, Continued

Models: SBVBP(C) SBVBN(C)

1 32
Download 32 pages 50.01 Kb
Page 15
Image 15
INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

OWNER’S MANUAL

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

Gas Valve

Equipment

Propane/

LP Supply

Shutoff

Tank

Valve

 

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 34. If wires are not connected as shown, the switch will not work.

2.Route the 25 ft. wire through openings provided on the sides of the burner sys- tem to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

Figure 32 - Checking Gas Joints for Propane/LP Gas Burner System

Equipment

Shutoff

Valve

Gas Meter

Gas Valve

Figure 33 - Checking Gas Joints for Natural Gas Burner System

To Control

Switch or

Optional

Accessory

Figure 34 - Control Valve Terminals

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.

Manual background WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Open lower door panel. The valve is attached to the underside of the burner system assembly.

2.Disconnect from the valve the wires running from the ON/OFF switch.

Continued

106828

15

For more information, visit www.desatech.com

Page 15
Image 15
Vanguard Heating SBVBP(C) INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2, INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1