® SBVBN(C) AND SBVBP(C)
CAST IRON STOVE AND BURNER SYSTEM
PRE-INSTALLATION PREPARATION
WARNING: A qualified in- staller or service person must install stove and burner system. Follow all local codes.
CAUTION: This stove with burner system creates warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove with burner system where impurities (such as tobacco smoke, aromatic candles, clean- ing fluids, oil or kerosene lamps,
On Wall with Vertical | Corner Installation |
Termination Through | with Vertical |
Ceiling | Termination |
| Through Ceiling |
Figure 2 - Common Stove Locations
Ceiling
etc.) in the air exist, may discolor walls.
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient loca- tion for your Vanguard
42"
36"
from
Front
4"
from
Back
Wall
4" |
6" |
Front |
When deciding the location of your stove, follow these rules:
Floor
29"
Figure 3 - Clearances for Standard Installation
1. | Do not connect this stove and burner |
| sytem to a chimney flue serving a |
| separate |
| appliance. |
2. | Due to high temperatures, do not lo- |
| cate this stove in high traffic areas or |
| near furniture or draperies. |
3. | Proper clearances must be maintained, |
| see Figures 3 and 4. |
4. | This stove is a freestanding unit de- |
| signed to set directly on the floor. If |
| your stove is to be installed directly on |
| carpeting, vinyl tile, or any combustible |
| material other than wood, it must be |
| installed on a metal or wood panel ex- |
| tending the full width and depth of the |
4" 4"
26 1/4"
Front
19 1/2"
stove. See Figure 5. |
Figure 4 - Clearance for Corner Installation Figure 5 - Stove With Burner System Bottom Dimensions
For more information, visit www.desatech.com | 4 | 106828 |