PRE-INSTALLATION PREPARATION

etc.) in the air exist, may discolor walls.LOCATION AND SPACE REQUIREMENTSManual backgroundManual background® SBVBN(C) AND SBVBP(C)

CAST IRON STOVE AND BURNER SYSTEM

PRE-INSTALLATION PREPARATION

Manual background WARNING: A qualified in- staller or service person must install stove and burner system. Follow all local codes.

Manual background CAUTION: This stove with burner system creates warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove with burner system where impurities (such as tobacco smoke, aromatic candles, clean- ing fluids, oil or kerosene lamps,

On Wall with Vertical

Corner Installation

Termination Through

with Vertical

Ceiling

Termination

 

Through Ceiling

Figure 2 - Common Stove Locations

Ceiling

etc.) in the air exist, may discolor walls.

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient loca- tion for your Vanguard B-vent cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows, or doors. Figure 2 shows some common locations. Read all venting infor- mation in this manual. Be aware of all restric- tions and precautions before deciding the exact location for your stove.

42"

36"

from

Front

4"

from

Back

Wall

4"

6"

Front

When deciding the location of your stove, follow these rules:

Floor

29"

Figure 3 - Clearances for Standard Installation

1.

Do not connect this stove and burner

 

sytem to a chimney flue serving a

 

separate solid-fuel burning fireplace or

 

appliance.

2.

Due to high temperatures, do not lo-

 

cate this stove in high traffic areas or

 

near furniture or draperies.

3.

Proper clearances must be maintained,

 

see Figures 3 and 4.

4.

This stove is a freestanding unit de-

 

signed to set directly on the floor. If

 

your stove is to be installed directly on

 

carpeting, vinyl tile, or any combustible

 

material other than wood, it must be

 

installed on a metal or wood panel ex-

 

tending the full width and depth of the

4" Manual backgroundManual background 4"

26 1/4"

Front

19 1/2"

stove. See Figure 5.

Figure 4 - Clearance for Corner Installation Figure 5 - Stove With Burner System Bottom Dimensions

For more information, visit www.desatech.com