® SBVBN(C) AND SBVBP(C)
CAST IRON STOVE AND BURNER SYSTEM
CLEANING AND MAINTENANCE
WARNING: Turn off burner system and let cool before cleaning.
CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of stove with burner system clean. Inspect these areas of stove and burner system before each use. Have burner system inspected yearly by a qualified service person. Burner system may need more frequent cleaning due to exces- sive lint from carpeting, bedding material, pet hair, etc.
GLASS DOOR
WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate burner system with the glass door re- moved, cracked, or broken.
WARNING: Do not use abra- sive cleaners as this may damage glass. Use a
Glass must be cleaned periodically. During
WARNING: Only parts sup- plied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 26). This glass door panel is a complete unit. No substitute materials may be used.
CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep chil- dren and pets away from glass.
If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 17). Vacuum all glass pieces with a shop vac.
CAUTION: Do not vacuum if pieces are hot.
Use only the ceramic glass door replace- ment intended for this burner system (see Replacement Parts, page 26 for details on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 17 for instructions for replacing glass door.
WARNING: Do not operate burner system with the glass door removed, cracked, or broken.
PILOT AND BURNERS
•Remove ember material before clean- ing burners and replace when cleaning is complete.
•Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.
•Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.
LOGS
•If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, page 18, to properly replace logs.
•Use a vacuum cleaner to remove any car- bon
•Replace log(s) if broken. See Replace- ment Parts on page 26.
•Replace ember material periodically as needed. See Replacement Parts on page 26.
VENTING SYSTEM
Conduct annual inspection of the venting system following these guidelines:
1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced imme- diately by a qualified service person.
2.Remove the vent cap and shine a flashlight into the vent. Remove any foreign material.
3.Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many el- bows, or exterior portions of the sys- tem being exposed to cold weather.
4.Inspect joints to verify that no pipe sec- tion or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.
For more information, visit www.desatech.com | 22 | 106828 |