OPTIONAL REMOTE

Thermostat Control OperationGHRC Series Operation:GHRCTA Series Operation:Manual background® SBVBN(C) AND SBVBP(C)

CAST IRON STOVE AND BURNER SYSTEM

OPERATING STOVE WITH B-VENT BURNER SYSTEM

Continued

OPTIONAL REMOTE

Selector Switch in

Remote Position

(Optional Remote

Control)

ON

OFF

REMOTE

Control Knob in On Position

O

H

 

 

L

 

ON

 

I

 

 

 

 

T

 

 

 

O

OFF

 

 

L

 

 

 

I

 

 

 

P

 

• In the AUTO mode, the thermostat

in the hand-held remote unit con-

trols the room temperature. To in-

crease the room temperature, press

the top arrow of the TEMP button.

To lower the room temperature,

press the bottom arrow of the

TEMP button. At higher settings

OPERATION

Note: All remote control accessories must be purchased separately (See Accessories on page 27). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional GHRCTA Only) The thermo- stat control setting on the remote control unit can be set to any comfort level be- tween WARMER and COOLER. The burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the cen- tral heating system, etc.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions, page 19 .

Flame Adjustment Knob

Figure 49 - Setting the Selector Switch, control Knob, and Flame Adjustment Knob for Remote Operation

GHRC Series Operation:

2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.

GHRCTA Series Operation:

2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 50). The lights to the left of the button will show AUTO, ON, or OFF.

In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.

the heater will run longer.

IMPORTANT: This remote control

has been specially engineered to

take an air temperature sample ev-

ery 5.5 minutes in the auto mode.

It will not respond immediately to

the temperature setting being

turned up or down.

IMPORTANT: The hand-held re-

mote control unit must be near the

heater. Do not keep the hand-held

remote control unit too close to the

heater. The thermostat on the

hand-held remote control unit will

heat up too quickly and turn the

heater off.

3. To turn the burner off, press the

AUTO/ON/OFF button until OFF

lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off,

manually turn the control knob on the

heater to the OFF position.

1. After lighting, let pilot flame burn for

about one minute. Turn control knob

on the control valve to ON position.

Turn flame adjustment knob any-

where between HI and LO. Slide the

selector switch to the REMOTE posi-

tion. Note: The burners may light if

hand-held remote ON button was on

when selector switch was last turned

off. You can now turn the burners on

and off with either optional hand-held

remote control unit.

IMPORTANT: Do not leave the se-

lector switch in the REMOTE posi-

tion when the pilot is not lit. This will

Shows Temperature Setting

The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected

Increases Room

Temperature in

AUTO Mode

Decreases Room

Temperature in

AUTO Mode

Turns Burner On or Off and Allows You to Choose the Auto Setting

drain the battery.

IMPORTANT: Be sure to press the

ON/OFF buttons on the hand-held

remote control unit for up to 3 sec-

onds to assure proper operation.

Figure 50 - Hand-Held Thermostat Remote Control Unit Selections (GHRCTA Only)

For more information, visit www.desatech.com

20

106828

Page 20
Image 20
Vanguard Heating SBVBN(C) Optional Remote, Thermostat Control Operation, GHRC Series Operation, GHRCTA Series Operation