Installation Items Needed

OWNER’S MANUAL

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

Installation Items Needed

Before installing stove and burner system, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas con- nector (if allowed by local codes) (not provided)

* An CSA/AGA design-certified equip-

ment shutoff valve with 1/8" NPT tap is an

acceptable alternative to test gauge connec-

tion. Purchase the CSA/AGA design-certi-

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from burner system (see Figure 29).

Check your building codes for any special requirements for locating equipment shutoff valve to stoves.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

 CAUTION: Use only new, black iron or steel pipe. Inter- CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 29. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

fied equipment shutoff valve from your

dealer.

Figure 28 - External Regulator with Vent Pointing Down (Propane/LP Only)

For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 28. Pointing the vent down protects it from freezing rain or sleet.

Manual background CAUTION: Use only new, black iron or steel pipe. Inter-

Approved Flexible

Gas Line

3" Minimum

CSA/AGA Design- Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Natural - From Gas

Meter (5" W.C. to 10.5"

W.C. Pressure )

LP - From External Regulator (11" W.C. to 14" W.C. Pressure)

nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to burner sys- tem. If pipe is too small, undue loss of pressure will occur.

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

*The CSA/AGA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your dealer.

Figure 29 - Gas Connection