® DIRECT-VENT GAS FIREPLACE

VDDVF36PN/PP and VDDVF36STN/STP Series

VENTING INSTALLATION

Continued

INSTALLATION FOR VERTICAL TERMINATION

NOTICE: Use rigid pipe only. Flex venting is not to be used with a vertical termination.

1.Determine the route your vertical vent- ing will take. If ceiling joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 24) to avoid cutting loadbearing members. Note: Pay spe- cial attention to these installation in- structions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclo- sures, attic rafters, etc. Do not pack air spaces with insulation. Also note maxi- mum vertical rise of the venting sys- tem and any maximum horizontal off- set limitations. Offsets must fall within the parameters shown in Figure 13 on page 6.

2.Set the fireplace in desired location. Drop a plumb line down from the ceil- ing to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point.

Drop a plumb line from the inside of the roof to the locating hole in the ceil- ing. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point.

Roof

Flashing

Wall Strap

45° Elbow

Ceiling Firestop

Figure 24 - Offset with Wall Strap and 45°

Flat Ceiling Installation

1.Cut a 10" square hole in the ceiling us- ing the locating hole as a center point. The opening should be framed to 10"x10" (254mm x 254mm) inside di- mensions, as shown in Figure 17 on page 9 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceil- ing or a room, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 25).

2.Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. All connections must be sealed with high temperature silicone sealant as specified in the second warning state- ment on page 7. Be sure all pipe and elbow connections are fully twist- locked (see Figure 16, page 9).

3.Cut a hole in the roof using the locating hole as a center point. (Cover any ex- posed open vent pipes before cutting hole in roof.) The 10"x10" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combus- tible materials. Frame the opening as shown in Figure 17 on page 9.

If area above is a room, install firestop above framed hole.

If area above is not a room, install firestop below framed hole.

Figure 25 - Installing Firestop

4.Connect a section of pipe and extend up through the hole.

Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for

this purpose (see Figure 24). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less re- striction to the flow of the flue gases and intake air.

5.Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing as shown in Figure 24. There must be a 1" clearance from the vent pipe to combustible materials.

6.Continue to add pipe sections until the height of the vent cap meets the mini- mum building code requirements de- scribed in Figure 13 on page 6. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs, and other similar fac- tors may cause poor draft or down-draft- ing in high winds. Increasing the vent height may solve this problem.

7.Twist-lock the vent cap onto the last section of vent pipe and seal with high temperature silicone sealant as speci- fied in the second warning statement on page 7.

Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclo- surewithstandardconstructionmaterial.Make sure and meet the minimum allowable clear- ances to combustibles. Do not fill any of the required air spaces with insulation.

Cathedral Ceiling Installation

1.Remove shingles or other roof cover- ing as necessary to cut the rectangular hole for the support box. Mark the out- line of the cathedral ceiling support box on the roof sheathing using the locat- ing hole as a center point.

2.Cut the hole 1/8" larger than the sup- port box outline (see Figure 26, page 13).

12

106918

Page 12
Image 12
Vanguard Heating VDDVF36PN/PP, VDDVF36STN/STP Installation for Vertical Termination, Flat Ceiling Installation

VDDVF36STN/STP, VDDVF36PN/PP specifications

The Vanguard Heating VDDVF36PN/PP and VDDVF36STN/STP are premium direct vent gas fireplaces that seamlessly blend contemporary design with advanced heating technologies. These models are perfect for homeowners looking to enhance their living spaces while ensuring optimal warmth and comfort.

One of the key features of the VDDVF36 series is its powerful heating capacity. With a maximum input of 36,000 BTUs, these fireplaces can efficiently warm large rooms, making them an excellent choice for both new constructions and renovations. Their direct vent system allows for flexible installation options, as it can draw air from outside and exhaust gases without needing an existing chimney.

The design aesthetic of the VDDVF36PN/PP and VDDVF36STN/STP models is notably sleek and modern. Available in either a pristine perfect black finish or a striking stainless steel option, these units can complement a variety of interior styles. The large viewing area, framed by a stylish bezel, ensures that the flames are the focal point of the room, establishing a cozy ambiance.

Equipped with advanced electronic ignition, these fireplaces offer ease of use and reliability. The ignitor provides a fast and safe startup, eliminating the need for manual lighting and enhancing the user experience. Additionally, these units come with a built-in thermostatic control, allowing users to regulate temperatures effectively, ensuring consistent comfort while optimizing energy use.

The VDDVF36 series is also designed with safety in mind. An integrated safety shut-off system ensures that the fireplace will automatically turn off if any issues are detected, providing peace of mind for users. Furthermore, the screens and barriers are designed to prevent accidental contact with the flames, making them safe for households with children and pets.

In terms of maintenance, the VDDVF36 models are designed for easy access to components, making regular cleaning and servicing straightforward. The durable construction materials used in these fireplaces ensure longevity and reliability, promising years of efficient heating.

Overall, the Vanguard Heating VDDVF36PN/PP and VDDVF36STN/STP models represent the pinnacle of modern gas fireplace technology, combining powerful heating capabilities, stylish aesthetics, and advanced safety features into one outstanding unit. For homeowners seeking a reliable and attractive heating solution, these fireplaces are an excellent choice.