OWNER’S MANUAL
INSTALLATION
Continued
Installing
1.Remove battery cover on back of re- mote control unit.
2.Attach terminal wires to the battery (not included). Place battery into the battery housing.
3.Replace battery cover onto remote con- trol unit.
Battery
Cover Remote
TerminalControl Unit Wires
Battery
Housing
Figure 37 - Installing Battery in Hand- Held Remote Control Unit
pressures in excess of 1/2 psig. (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its indi- vidual manual
CAUTION: Do not kink flex- ible gas line.
CAUTION: Compounds used on threaded joints of gas piping shall be resistant to the action of Liquefied Petroleum (LP or pro- pane), and should be applied lightly to ensure excess sealant does not enter the gas line.
1.Install a sediment trap between the in- coming gas line and the gas control valve (see Figure 39). The sediment trap should extend down the center of the pipe. Refer to your local codes.
2.Prepare incoming gas line and check with local codes regarding the use of teflon tape. Complete your gas line in-
stallation by connecting incoming gas line with flexible gas line. Secure tightly with a wrench, but Do NOT
Overtighten.
WARNING: All gas piping and connections must be tested for leaks after the installation is completed.
After ensuring that the gas valve is open, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected and corrected.
Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.
WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier.
GAS LINE HOOK-UP
WARNING: Before you pro- ceed, make sure your gas supply is OFF.
WARNING: Gas line hookup
Key
Extension
| Wall |
| Appliance |
Back | |
Of |
|
Incoming 1/2" Gas Line Permitted by Local Codes
should be done by your gas sup- plier or a qualified service person.
A manual
Route a 1/2” NPT black iron gas line to- wards the appliance coming in from the left. It is recommended to route the pipe between the stand of the firebox and the surround of the fireplace (see Figure 39).
IMPORTANT: The appliance and its indi- vidual
Figure 38 - Typical Exterior Wall Gas | Sediment Trap (Not Supplied) | ||
Figure 39 - Sediment Trap | |||
| |||
|
|
|
|
| GAS RATING |
|
|
|
|
|
|
TYPE OF GAS | NATURAL |
| PROPANE/LP |
|
|
|
|
Max. Input Rating: | 30,000 Btu/hr |
| 28,000 Btu/hr |
|
|
|
|
Orifice Size | 7/64" |
| #52 |
|
|
|
|
Minimum Input Rating: | 21,000 Btu/hr |
| 20,000 Btu/hr |
(When the Valve is in |
|
|
|
the LOW Position) |
|
|
|
|
|
|
|
Manifold Pressure: | 3.5 in. WC |
| 10.0 in. WC |
|
|
|
|
**Minimum Supply Pressure: | 4.5 in. WC |
| 11.0 in. WC |
|
|
|
|
**Maximum Supply Pressure: | 10.5 in. WC |
| 13.0 in. WC |
|
|
|
|
** For the purpose of input adjustment. |
|
|
Continued
106918 | 17 |