OWNER’S MANUAL

INTRODUCTION

ModelsVDDVF36PN/PPseriesarethree-sided direct-vent gas fireplace with a sealed combus- tion chamber. Models VDDVF36STN/STP series are two-sided direct-vent gas fireplace with a sealed combustion chamber. All models use a millivolt gas control and a millivolt igni- tion system. All models have a manual HI/LO valve to control the flame height. A fan kit is available for these models as an option (see Accessories on page 28).

NOTICE: Check local building codes for area requirements be- fore installing this appliance.

Models VDDVF36PN and VDDVF36STN use NATURAL GAS ONLY.

Models VDDVF36PP and VDDVF36STP use PROPANE/LP GAS ONLY.

If you have any doubts as to which gas your particular appliance is approved and tested for, please check the AGA/CGA rating plate located at the interior of the appliance open- ing or consult your local distributor (see Figures 1 and 2, page 2).

BEFORE YOU BEGIN

Before beginning the installation of your appliance, read these instructions through completely.

This DESA appliance and its approved com- ponents are safe when installed according to this installation manual and operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A SAFETY

HAZARD!

The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions:

A)Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted in writing by DESA.

B)The use of any components part not ap- proved by DESA in combination with this DESA appliance.

C)Installation and/or operation in a man- ner other than instructed in this manual.

D)The burning of anything other than the type of gas approved for use in this gas appliance.

This appliance, when installed, must be elec- trically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANS/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANS Z223.1 or the Canadian Installation Code, CAN/CGA B149.

This appliance complies with ANS Z21.50- 1998/CSA 2.22-M48 as a VENTED GAS FIREPLACE. It is listed and tested by Inter- national Approval Services.

NOTICE: This appliance is in- tended to be used only for supple- mental heat.

WARNING: Installation and repair should be done by a quali- fied installer/service person. The appliance should be inspected before use, and at least annually thereafter by a qualified service person. More frequent cleaning may be required due to exces- sive lint from carpeting, bedding, pet hair, etc. It is imperative that the control compartments, burn- ers, and circulating air systems be kept clean.

SELECTING

LOCATION

To determine the safest and most efficient location for your appliance, consider the following guidelines:

1.The location must allow for proper clearances (see Clearances, page 4).

2.Consider a location where heat output would not be affected by drafts, air con- ditioning ducts, windows, or doors.

3.A location that avoids the cutting of joists or roof rafters makes installation easier.

In selecting a location, the following pre- cautions must be observed:

1.A projection may be ideal for a new ad- dition on an existing finished wall. See Horizontal Termination Configuration, pages 10 and 11, or Vertical Termina- tion Configuration, pages 13 and 14.

2.Do not locate appliance close to where gasoline or other flammable liquids may be stored. The appliance must be kept clear and free from combustible materials.

3.Do not connect this appliance to a chimney system used for solid fuel burning fireplace.

4.Due to high temperatures, do not lo- cate this appliance in high traffic areas or near furniture and draperies.

5.This fireplace may be installed in bed- rooms or bathrooms in accordance with local codes.

6.Never obstruct the openings of the ap- pliance or flow of ventilation air. Keep the control compartments accessible.

7.Do not use this appliance if any part has been under water. Immediately contact a local service technician to ex- amine the appliance and to replace any part(s) of the control ignition system and other related components that have submerged under water.

Figure 3 - Possible Installation of Peninsula Fireplace

106918

3

Page 3
Image 3
Vanguard Heating VDDVF36STN/STP, VDDVF36PN/PP installation manual Introduction, Selecting Location, Before YOU Begin

VDDVF36STN/STP, VDDVF36PN/PP specifications

The Vanguard Heating VDDVF36PN/PP and VDDVF36STN/STP are premium direct vent gas fireplaces that seamlessly blend contemporary design with advanced heating technologies. These models are perfect for homeowners looking to enhance their living spaces while ensuring optimal warmth and comfort.

One of the key features of the VDDVF36 series is its powerful heating capacity. With a maximum input of 36,000 BTUs, these fireplaces can efficiently warm large rooms, making them an excellent choice for both new constructions and renovations. Their direct vent system allows for flexible installation options, as it can draw air from outside and exhaust gases without needing an existing chimney.

The design aesthetic of the VDDVF36PN/PP and VDDVF36STN/STP models is notably sleek and modern. Available in either a pristine perfect black finish or a striking stainless steel option, these units can complement a variety of interior styles. The large viewing area, framed by a stylish bezel, ensures that the flames are the focal point of the room, establishing a cozy ambiance.

Equipped with advanced electronic ignition, these fireplaces offer ease of use and reliability. The ignitor provides a fast and safe startup, eliminating the need for manual lighting and enhancing the user experience. Additionally, these units come with a built-in thermostatic control, allowing users to regulate temperatures effectively, ensuring consistent comfort while optimizing energy use.

The VDDVF36 series is also designed with safety in mind. An integrated safety shut-off system ensures that the fireplace will automatically turn off if any issues are detected, providing peace of mind for users. Furthermore, the screens and barriers are designed to prevent accidental contact with the flames, making them safe for households with children and pets.

In terms of maintenance, the VDDVF36 models are designed for easy access to components, making regular cleaning and servicing straightforward. The durable construction materials used in these fireplaces ensure longevity and reliability, promising years of efficient heating.

Overall, the Vanguard Heating VDDVF36PN/PP and VDDVF36STN/STP models represent the pinnacle of modern gas fireplace technology, combining powerful heating capabilities, stylish aesthetics, and advanced safety features into one outstanding unit. For homeowners seeking a reliable and attractive heating solution, these fireplaces are an excellent choice.