OWNER’S MANUAL
VENTING | Vanguard Rigid Venting (Cont.) | |||||
INSTALLATION | Number | Description |
| |||
*SVK | Snorkel Rigid Vent Kit | |||||
Continued |
| Includes: 7" x 30° Elbow, 7" x 4' | ||||
HIGH ALTITUDE |
| Galvanized Pipe, 7" x 90° El- | ||||
| bow, 7" Adjustable Galvanized | |||||
INSTALLATION |
| Pipe | ||||
Your Vanguard |
| Snorkel Termination, RTV Sili- | ||||
| cone and 28 Screws | |||||
been AGA tested and approved for eleva- |
| |||||
*RVF | Roof Rigid Vent Kit | |||||
tions from | ||||||
| Includes: Flue Restrictor, Storm | |||||
for elevations from |
| |||||
| Collar, 7" x 30° Elbow, 7" x 4' | |||||
When installing this fireplace at an elevation |
| |||||
| Galvanized Pipe, 7" x 2' Galva- | |||||
above 2000 feet (in the USA), you may need |
| |||||
| nized Pipe, 7" Adjustable Gal- | |||||
to decrease the input rating by changing the |
| |||||
| vanized Pipe | |||||
existing burner orifice to a smaller size. Re- |
| |||||
| Support, Roof Flashing, RTV | |||||
duce input 4% for each 1000 feet above sea |
| |||||
| Silicone, Vertical Termination, | |||||
level. Check with your local gas company for |
| |||||
| and 26 screws | |||||
proper orifice size identification. |
| |||||
D1000 | 7" x 12" Galvanized Coaxial | |||||
When installing this fireplace at an eleva- | ||||||
| Pipe (6 pcs.) | |||||
tion above 4500 feet (in Canada), check | D1010 | 7" x 24" Galvanized Coaxial | ||||
with local authorities. |
| Pipe (6 pcs.) | ||||
Consult your local gas company to help de- | D1020 | 7" x 48" Galvanized Coaxial | ||||
termine the proper orifice for your location. |
| Pipe (6 pcs.) | ||||
For assistance with any high altitude instal- | D1030 | 7" Adjustable | ||||
| Galvanized Coaxial Pipe | |||||
lation contact DESA International’s Tech- |
| |||||
nical Service Department at |
| (6 pcs.) | ||||
LOG | D1050 | 7" x 6" Galvanized Coaxial | ||||
|
|
| ||||
PARTS LISTS FOR VENTING |
| Pipe (6 pcs.) | ||||
D2000 | 7" x 90° Elbow (6 pcs.) | |||||
KITS AND COMPONENTS | ||||||
D2010 | 7" x 45° Elbow (6 pcs.) | |||||
|
|
| ||||
*NOTICE: The 7" x 30° Elbow sup- |
| D2060 | 7" x 45° Starter Elbow | |||
plied with kits CVK, BVK, SVK, |
| D3000 | Wall Strap/Offset Support | |||
and RVF cannot be used. It MUST |
|
| (6 pcs.) | |||
be replaced with a 7" x 45º Starter |
| D3010 | Storm Collar (6 pcs.) | |||
Elbow (D2060). |
| |||||
| D3020 | Wall Thimble (6 pcs.) | ||||
|
|
| ||||
|
|
| ||||
Vanguard Rigid Venting | D3050 | Vertical Restrictor (6 pcs.) | ||||
Number | Description | D3060 | Ceiling Firestop/Support | |||
|
|
|
| (6 pcs.) | ||
*CVK | Corner Vent Kit |
| ||||
|
|
| ||||
| Includes: 7" x 30º Elbow, 7" x 90ºD3070 | Rectangular Horizontal Rigid | ||||
| Elbow, 7" Adjustable Galvanized |
| Vent Termination Cap | |||
| D3090 | Cathedral Ceiling Support | ||||
| Pipe | |||||
| Thimble, Horizontal Termina- |
| Box | |||
| tion, RTV Silicone and 20 Screws | D4000 | Roof Flashing | |||
*BVK | Basement Rigid Vent Kit | D4010 | Roof Flashing | |||
| Includes: 7" x 30° Elbow, 7" x 4' | D4020 | Flex Connector (6 pcs.) | |||
| Galvanized Pipe, 7" x 90° El- | D4030 | Flex Wall Thimble (6 pcs.) | |||
| bow, 7" Adjustable Galvanized | |||||
| D4040 | 4" Hose Clamp (6 pcs.) | ||||
| Pipe | |||||
| D4050 | 7" Hose Clamp (6 pcs.) | ||||
| Horizontal Termination, RTV | |||||
| Silicone and 20 Screws | D5000 | Vinyl Siding Standoff (6 pcs.) |
Vanguard Flexible Venting
Number Description
FGFVK Flex Ground Floor Vent Kit Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4' Flexible Pipe, Wall Thimble, Horizontal Termination, (4) Spacer Springs,
(2)4" Hose Clamps, (2) 7" Hose Clamps, RTV Silicone, and 10 Screws
D1040 7" x 25' Coaxial Flex Pipe
with Spacer Springs
D3080 Rectangular Horizontal
Flex Termination Cap
SIMPSON
Number Description
9027" x 48" Pipe
9037" x 36" Pipe
9047" x 24" Pipe
9067" x 12" Pipe
9077" x 9" Pipe
9087" x 6" Pipe
9117" Adjustable
940Wall Thimble
941Cathedral Ceiling Support Box
943Roof Flashing
943S Roof Flashing
9457" x 45° Elbow
950Vinyl Siding Standoff
953Storm Collar
963Ceiling Firestop
98136" Snorkel Termination
984HorizontalTerminationVentCap
988Wall Strap
9907" x 90° Elbow
991Vertical High Wind Termination
105706 | 15 |