Vanguard Heating VDVF36PP, VDVF36STP Installation, Continued, Vanguard Rigid Venting Cont

Models: VDVF36PN VDVF36STP VDVF36STN VDVF36PP

1 30
Download 30 pages 14.56 Kb
Page 15
Image 15
VENTING

OWNER’S MANUAL

VENTING

Vanguard Rigid Venting (Cont.)

INSTALLATION

Number

Description

 

*SVK

Snorkel Rigid Vent Kit

Continued

 

Includes: 7" x 30° Elbow, 7" x 4'

HIGH ALTITUDE

 

Galvanized Pipe, 7" x 90° El-

 

bow, 7" Adjustable Galvanized

INSTALLATION

 

Pipe (7-12"), Wall Thimble, 36"

Your Vanguard direct-vent fireplace has

 

Snorkel Termination, RTV Sili-

 

cone and 28 Screws

been AGA tested and approved for eleva-

 

*RVF

Roof Rigid Vent Kit

tions from 0-2000 feet and CGA certified

 

Includes: Flue Restrictor, Storm

for elevations from 0-4500 feet.

 

 

Collar, 7" x 30° Elbow, 7" x 4'

When installing this fireplace at an elevation

 

 

Galvanized Pipe, 7" x 2' Galva-

above 2000 feet (in the USA), you may need

 

 

nized Pipe, 7" Adjustable Gal-

to decrease the input rating by changing the

 

 

vanized Pipe (7-12"), Firestop

existing burner orifice to a smaller size. Re-

 

 

Support, Roof Flashing, RTV

duce input 4% for each 1000 feet above sea

 

 

Silicone, Vertical Termination,

level. Check with your local gas company for

 

 

and 26 screws

proper orifice size identification.

 

D1000

7" x 12" Galvanized Coaxial

When installing this fireplace at an eleva-

 

Pipe (6 pcs.)

tion above 4500 feet (in Canada), check

D1010

7" x 24" Galvanized Coaxial

with local authorities.

 

Pipe (6 pcs.)

Consult your local gas company to help de-

D1020

7" x 48" Galvanized Coaxial

termine the proper orifice for your location.

 

Pipe (6 pcs.)

For assistance with any high altitude instal-

D1030

7" Adjustable (7-12")

 

Galvanized Coaxial Pipe

lation contact DESA International’s Tech-

 

nical Service Department at 1-800-DESA-

 

(6 pcs.)

LOG (1-800-337-2564).

D1050

7" x 6" Galvanized Coaxial

 

 

 

PARTS LISTS FOR VENTING

 

Pipe (6 pcs.)

D2000

7" x 90° Elbow (6 pcs.)

KITS AND COMPONENTS

D2010

7" x 45° Elbow (6 pcs.)

 

 

 

*NOTICE: The 7" x 30° Elbow sup-

 

D2060

7" x 45° Starter Elbow

plied with kits CVK, BVK, SVK,

 

D3000

Wall Strap/Offset Support

and RVF cannot be used. It MUST

 

 

(6 pcs.)

be replaced with a 7" x 45º Starter

 

D3010

Storm Collar (6 pcs.)

Elbow (D2060).

 

 

D3020

Wall Thimble (6 pcs.)

 

 

 

 

 

 

Vanguard Rigid Venting

D3050

Vertical Restrictor (6 pcs.)

Number

Description

D3060

Ceiling Firestop/Support

 

 

 

 

(6 pcs.)

*CVK

Corner Vent Kit

 

 

 

 

 

Includes: 7" x 30º Elbow, 7" x 90ºD3070

Rectangular Horizontal Rigid

 

Elbow, 7" Adjustable Galvanized

 

Vent Termination Cap

 

D3090

Cathedral Ceiling Support

 

Pipe (7-12"), 6" Pipe, Wall

 

Thimble, Horizontal Termina-

 

Box

 

tion, RTV Silicone and 20 Screws

D4000

Roof Flashing 6/12-9/12

*BVK

Basement Rigid Vent Kit

D4010

Roof Flashing 9/12-12/12

 

Includes: 7" x 30° Elbow, 7" x 4'

D4020

Flex Connector (6 pcs.)

 

Galvanized Pipe, 7" x 90° El-

D4030

Flex Wall Thimble (6 pcs.)

 

bow, 7" Adjustable Galvanized

 

D4040

4" Hose Clamp (6 pcs.)

 

Pipe (7-12"), Wall Thimble,

 

D4050

7" Hose Clamp (6 pcs.)

 

Horizontal Termination, RTV

 

Silicone and 20 Screws

D5000

Vinyl Siding Standoff (6 pcs.)

Vanguard Flexible Venting

Number Description

FGFVK Flex Ground Floor Vent Kit Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4' Flexible Pipe, Wall Thimble, Horizontal Termination, (4) Spacer Springs,

(2)4" Hose Clamps, (2) 7" Hose Clamps, RTV Silicone, and 10 Screws

D1040 7" x 25' Coaxial Flex Pipe

with Spacer Springs

D3080 Rectangular Horizontal

Flex Termination Cap

SIMPSON DURA-VENT GS 4" x 6 5/8 "

Number Description

9027" x 48" Pipe

9037" x 36" Pipe

9047" x 24" Pipe

9067" x 12" Pipe

9077" x 9" Pipe

9087" x 6" Pipe

9117" Adjustable (11"-14 5/8") Pipe

940Wall Thimble

941Cathedral Ceiling Support Box

943Roof Flashing 0/12-6/12

943S Roof Flashing 7/12-12/12

9457" x 45° Elbow

950Vinyl Siding Standoff

953Storm Collar

963Ceiling Firestop

98136" Snorkel Termination

984HorizontalTerminationVentCap

988Wall Strap

9907" x 90° Elbow

991Vertical High Wind Termination

105706

15

Page 15
Image 15
Vanguard Heating VDVF36PP, VDVF36STP Installation, Continued, Vanguard Rigid Venting Cont, Vanguard Flexible Venting