Vanguard Heating VDVF36STN, VDVF36STP, VDVF36PN, VDVF36PP Installation, Continued, Gas Line Hook-Up

Models: VDVF36PN VDVF36STP VDVF36STN VDVF36PP

1 30
Download 30 pages 14.56 Kb
Page 17
Image 17
GAS LINE HOOK-UP

OWNER’S MANUAL

INSTALLATION

Continued

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery

Cover Remote

TerminalControl Unit Wires

9-Volt Battery

Manual background Battery

Housing

Figure 37 - Installing Battery in Hand- Held Remote Control Unit

pressures in excess of 1/2 psig. (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its indi- vidual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.5 kPa).

Manual background CAUTION: Do not kink flex- ible gas line.

Manual background CAUTION: Compounds used on threaded joints of gas piping shall be resistant to the action of Liquefied Petroleum (LP or pro- pane), and should be applied lightly to ensure excess sealant does not enter the gas line.

1.Install a sediment trap between the in- coming gas line and the gas control valve (see Figure 39). The sediment trap should extend down the center of the pipe. Refer to your local codes.

2.Prepare incoming gas line and check with local codes regarding the use of teflon tape. Complete your gas line in-

stallation by connecting incoming gas line with flexible gas line. Secure tightly with a wrench, but Do NOT

Overtighten.

Manual background WARNING: All gas piping and connections must be tested for leaks after the installation is completed.

After ensuring that the gas valve is open, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected and corrected.

Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.

Manual background WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier.

GAS LINE HOOK-UP

Manual background WARNING: Before you pro- ceed, make sure your gas supply is OFF.

Manual background WARNING: Gas line hookup

Shut-Off Valve

Key

Extension

 

Wall

 

Appliance

Back

Of

 

Incoming 1/2" Gas Line Permitted by Local Codes

should be done by your gas sup- plier or a qualified service person.

A manual shut-off valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shut-off valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 38.

Route a 1/2” NPT black iron gas line to- wards the appliance coming in from the left. It is recommended to route the pipe between the stand of the firebox and the surround of the fireplace (see Figure 39).

IMPORTANT: The appliance and its indi- vidual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test

Figure 38 - Typical Exterior Wall Gas

Sediment Trap (Not Supplied)

Shut-Off Installation

Figure 39 - Sediment Trap

 

 

 

 

 

 

GAS RATING

 

 

 

 

 

 

TYPE OF GAS

NATURAL

 

PROPANE/LP

 

 

 

 

Max. Input Rating:

30,000 Btu/hr

 

28,000 Btu/hr

 

 

 

 

Orifice Size (0-4,500 Ft.):

7/64"

 

#52

 

 

 

 

Minimum Input Rating:

21,000 Btu/hr

 

20,000 Btu/hr

(When the Valve is in

 

 

 

the LOW Position)

 

 

 

 

 

 

 

* Maximum Output Rating:

21,000 Btu/hr

 

20,000 Btu/hr

 

 

 

 

Manifold Pressure:

3.5 in. WC

 

10.0 in. WC

 

 

 

 

**Minimum Supply Pressure:

4.5 in. WC

 

11.0 in. WC

 

 

 

 

**Maximum Supply Pressure:

10.5 in. WC

 

13.0 in. WC

 

 

 

 

* 70% Efficiency (flue loss calculation).

 

 

** For the purpose of input adjustment.

 

Continued