Vanguard Heating VDVF36PP Service Hints, Technical Service, Replacement Parts, Wiring Diagram

Models: VDVF36PN VDVF36STP VDVF36STN VDVF36PP

1 30
Download 30 pages 14.56 Kb
Page 23
Image 23
SERVICE HINTS

OWNER’S MANUAL

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burner will produce flames and soot

fireplace will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

You can also visit DESA International’s Technical Services web site at

www.desatech.com.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Ser- vice Department at 1-800-323-5190 for re- ferral information.

When calling DESA International, have ready

your name

your address

WIRING DIAGRAM

 

 

 

 

 

Piezo Ignitor

Pilot

Piezo Ignitor

Do Not

 

 

Thermocouple

Thermopile

 

 

 

Connect

 

 

 

 

 

 

 

 

 

 

Pilot

 

To 120V

 

 

 

 

Gas Line

 

N.O.SW

 

 

 

 

 

 

(Wall Switch

 

 

Incoming

 

 

 

Supplied)

 

 

 

TH

 

 

N.O.SW

 

Main

Control

 

 

 

TP

 

 

 

Gas

Valve

 

 

(Wall Switch

 

 

 

 

Not Supplied)

 

Supply

TPTH

 

 

 

 

 

Field Wire

 

 

 

* Remote

 

 

 

 

 

BLK

 

 

 

 

Control

 

Incoming

 

 

 

 

 

 

 

 

 

Wireway

 

WHT

120V AC

 

 

 

 

 

(Fuse Box

 

Blower

Variable Speed

 

GRN

or

 

Control

Electrical Rating:

 

 

Breaker)

* Use Extension Cord (Included With Kit)

 

Connectors

120v, 60Hz, 0.7A

GND

 

 

 

 

 

(Not Supplied)

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

type of gas used (propane/LP or natural

 

gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

105706

23

Page 23
Image 23
Vanguard Heating VDVF36PP Service Hints, Technical Service, Replacement Parts, Wiring Diagram, When Gas Quality Is Bad