OWNER’S MANUAL

INTRODUCTION

Models VDVF36PN/PP series are three- sided direct-vent gas fireplace heaters with a sealed combustion chamber. Models VDVF36STN/STP series are two-sided di- rect-vent gas fireplace heaters with a sealed combustion chamber. All models use a mil- livolt gas control and a millivolt ignition system. All models have a manual HI/LO valve to control the flame height. A fan kit is available for these models as an option.

NOTICE: Check local building codes for area requirements be- fore installing this appliance.

Models VDVF36PN and VDVF36STN use NATURAL GAS ONLY.

Models VDVF36PP and VDVF36STP use PROPANE/LP GAS ONLY.

If you have any doubts as to which gas your particular appliance is approved and tested for, please check the AGA/CGA rating plate located at the interior of the appliance open- ing or consult your local distributor (see Figures 1 and 2, page 2).

BEFORE YOU BEGIN

Before beginning the installation of your appliance, read these instructions through completely.

This DESA appliance and its approved com- ponents are safe when installed according to this installation manual and operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A SAFETY

HAZARD!

The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions:

A)Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted in writing by DESA.

B)The use of any components part not ap- proved by DESA in combination with this DESA appliance.

C)Installation and/or operation in a man- ner other than instructed in this manual.

D)The burning of anything other than the type of gas approved for use in this gas appliance.

This appliance, when installed, must be elec- trically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANS/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANS Z223.1 or the Canadian Installation Code, CAN/CGA B149.

This appliance complies with ANS Z21.88- 1998 and CSA 2.33-M98 as a VENTED GAS FIREPLACE HEATER. It is listed and tested by International Approval Services.

NOTICE: This appliance is in- tended to be used only for supple- mental heat.

WARNING: Installation and repair should be done by a quali- fied service person. The appliance should be inspected before use, and at least annually thereafter by a qualified service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding, pet hair, etc. It is imperative that the control com- partments, burners, and circulat- ing air systems be kept clean.

SELECTING

LOCATION

To determine the safest and most efficient location for your appliance, consider the following guidelines:

1.The location must allow for proper clearances (see Clearances, page 4).

2.Consider a location where heat output would not be affected by drafts, air con- ditioning ducts, windows, or doors.

3.A location that avoids the cutting of joists or roof rafters makes installation easier.

In selecting a location, the following pre- cautions must be observed:

1.A projection may be ideal for a new ad- dition on an existing finished wall. See Horizontal Termination Configuration, pages 10 and 11, or Vertical Termina- tion Configuration, pages 13 and 14.

2.Do not locate appliance close to where gasoline or other flammable liquids may be stored. The appliance must be kept clear and free from combustible materials.

3.Do not connect this appliance to a chimney system used for solid fuel burning fireplace.

4.Due to high temperatures, do not lo- cate this appliance in high traffic areas or near furniture and draperies.

5.This fireplace may be installed in bed- rooms or bathrooms in accordance with local codes.

6.Never obstruct the openings of the ap- pliance or flow of ventilation air. Keep the control compartments accessible.

7.Do not use this appliance if any part has been under water. Immediately contact a local service technician to ex- amine the appliance and to replace any part(s) of the control ignition system and other related components that have submerged under water.

Figure 3 - Possible Installation of Peninsula Fireplace

105706

3

Page 3
Image 3
Vanguard Heating VDVF36PP, VDVF36STP, VDVF36STN, VDVF36PN Introduction, Selecting Location, Before YOU Begin

VDVF36PN, VDVF36STP, VDVF36STN, VDVF36PP specifications

Vanguard Heating has established itself as a noteworthy player in the heating solutions market, and its latest offerings, the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN models, exemplify their commitment to innovative technology and user-centric design. These models are engineered to provide efficient heating solutions while enhancing the aesthetic appeal of any living space.

A standout feature of the Vanguard VDVF36 series is its sleek, modern design. These units seamlessly integrate into various architectural styles, making them an attractive option for both contemporary and traditional interiors. The VDVF36STN, for instance, showcases a stunning see-through option, allowing homeowners to enjoy the ambiance of flames from multiple angles.

These heating appliances utilize advanced gas burner technology, ensuring high thermal efficiency while maintaining a clean-burning flame. This results in reduced carbon emissions, making the VDVF36 series an environmentally responsible choice without compromising performance. The burners are designed to provide even heat distribution, minimizing cold spots and creating a comfortable atmosphere in the desired space.

One of the prominent technologies included in the Vanguard VDVF36 models is the remote control capability. Users can effortlessly manage temperature settings and flame height from the comfort of their seats, enhancing convenience and user experience. Additionally, the units come equipped with multiple flame settings, allowing users to customize the ambiance to match their mood or occasion.

Safety is a top priority in the design of the VDVF36 series. Each model features a built-in safety shutoff system, which automatically turns the unit off in the event of a malfunction, providing peace of mind for homeowners. Additionally, the glass front design incorporates advanced tempered glass technology, ensuring safety and durability while providing an unobstructed view of the flames.

The VDVF36 series also boasts easy installation and maintenance features. Designed for straightforward retrofitting, these units can be integrated into existing chimney systems or used with direct venting options, giving flexibility to home installations. Maintenance is simplified thanks to the accessible components, making routine checks hassle-free.

In summary, the Vanguard Heating VDVF36 models, including the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN, combine advanced technology with aesthetic appeal and safety features, offering users an efficient and stylish heating solution for their homes. Whether enhancing the comfort of a living room or adding charm to a gathering space, these models stand out as exceptional choices in modern heating technology.