Vanguard Heating VDVF36STN, VDVF36STP Venting Installation, Continued, Vent Pipe Connections

Models: VDVF36PN VDVF36STP VDVF36STN VDVF36PP

1 30
Download 30 pages 14.56 Kb
Page 9
Image 9
Figure 16 - Vent Pipe Connections

OWNER’S MANUAL

VENTING INSTALLATION

Continued

3.Attach vent pipe assembly to the fire- place. Set fireplace in front of it’s per- manent location to insure minimum clearances. Mark the wall for a 10" square hole (for noncombustible ma- terial such as masonry block or con- crete, a 7 1/2" diameter hole is accept- able). See Figure 17. The center of the hole should line up with the center- line of the horizontal rigid vent pipe. Cut a 10"x10" (254mm x 254mm) square hole through combustible ex- terior wall (7 1/2" [190mm] diameter hole if noncombustible). Frame as nec- essary (see Figure 17).

 

4" Clamp

Female

7" Clamp

Locking

 

Lugs

 

 

Spacer

 

Spring

Male

4" Flex

Pipe

Slots

 

 

7" Flex

 

Pipe

Rigid Vent Pipe Flexible Vent Pipe

Figure 16 - Vent Pipe Connections

Vent Opening

Combustible Wall

10"

(254mm)

10"

(254mm)

(Framing

4.Apply a bead of non-hardening mastic around the outside edge of the vent cap. Position the vent cap in the center of the 7 1/2" or 10" hole on the exterior wall with the arrow on the vent cap pointing up. Insure proper clearance of 1" to combustibles is maintained. At- tach the vent cap with four wood screws supplied (see Figure 18). Note: Re- place the wood screws with appropri- ate fasteners for stucco, brick, concrete, or other types of siding.

Figure 18 - Installing Horizontal Vent Cap WARNING: Do not recess vent termination in to any wall. This will cause a fire hazard.

For vinyl siding use vinyl siding stand- offs between vent cap and exterior wall. The vinyl siding standoff prevents ex- cessive heat from melting the vinyl sid- ing material. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of the standoff in- stead of the vent cap assembly. Use wood screws provided to attach the standoff. See Figure 19.

5.Slide the wall thimble over the vent pipe before connecting the horizontal run to the vent cap (see Figure 20).

Apply Mastic to All Four Sides

UP

Figure 19 - Installing Vinyl Siding StandoffWood

Screw

Vent Cap

Figure 18 - Installing Horizontal Vent Cap

6.Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the horizontal termination. The pipe overlap should be a minimum of 1 1/4". Apply silicone to the connection. Fasten all vent connec- tions with screws provided. Refer to Framing on pages 4 and 5 for instruc- tions on securing unit to framing or floor.

7.Slide the wall thimble against the inte- rior wall surface and attach with screws provided (see Figure 20).

Cut Vinyl Siding

Away to Fit

Standoff

Wood Screw

Standoff

UP

Nut

Bolt

Apply Mastic

to All Four Sides Vent Cap

Figure 19 - Installing Vinyl Siding Standoff

Interior Wall

Surface

Wall

Thimble

Vent Cap

Screw

(Horizontal

 

Vent Opening

Detail)

Termination)

Horizontal

Vent Pipe

 

Non-Combustible Wall

71/2"

(190mm)

Figure 17 - Vent Opening Requirements

Figure 20 - Connecting Vent Cap with Horizontal Vent Pipe

Continued

105706

9

Page 9
Image 9
Vanguard Heating VDVF36STN Venting Installation, Continued, Vent Pipe Connections, Installing Horizontal Vent Cap