DVHVAC36

Operating Instructions

General Glass Information

Only glass approved by Vermont Casting, Majestic Products should be used on this fireplace.

The use of non-approved replacement glass will void all product warranties.

Care must be taken to avoid breakage of the glass.

Do not operate appliance with glass front removed, cracked or broken.

Replacement of the glass (complete with gasket) is available through your Majestic Fireplaces dealer and should be done by a licensed qualified service person.

Louvre Removal

Glass

Frame

 

 

Fireplace

 

 

Front

Clamps

 

 

 

 

Window

 

 

Frame

 

 

Assembly

Window

 

Pull Clamp Hook

Frame

Push

Assem-

 

bly

Clamp

 

 

Handle

FP1405

 

 

To remove top louvre, pull louvre up and then lift out. (Fig. 35)

2.

Top Lou-

1.vre Assembly

Fig. 36 Window frame assembly removal.

be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present.

Clean glass after first two weeks of operation.

FP1227

Window Frame As- sembly

Do not clean glass when it is hot. Do not use abrasive cleaners.

Fig. 35 Remove top louvre as- sembly.

Window Frame Assembly Removal

1.Shut off gas.

2.Let the fireplace cool if it has been operating.

3.Remove top louvre assembly. (See Louvre Removal)

4.Open the lower louvre assembly.

5.Release the two clamps at the bottom of the window frame by pulling down on the clamp handles. (Fig. 36)

6.Tilt window frame assembly out slightly at the bot- tom, lift the frame up and away from the fireplace.

7.To replace window frame assembly, reverse this procedure.

Glass Cleaning

It will be necessary to clean the glass periodically. During start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended the glass

Do not strike or slam the glass.

Installation of Logs &

Burner Lava Rock Material

Refer to Figure 37.

1.Remove window frame assembly.

2.Remove logs from packaging.

3.Place rear log (B15) on rear bracket (ensure log is seated properly, levelled and centered to the unit), so it will not move from side to side and it is firmly positioned on the bracket.

4.Slip front ember log (B12) down in the front deflector.

5.Place front left log (B13) on top burner, left side. Use log's bottom holes to locate it into the left bracket log locator studs.

6.Place front right log (B14) on top of burner, right side. Use log's bottom holes to locate it into the right bracket log locator studs.

7.Place burner lava rock on top of burner. (Fig. 37) Refer to "Setting Temperature Rise".

8.Place top right log (B17) onto locator notches. Ensure log is secure.

20

10001195

Page 20
Image 20
Vermont Casting DVHVAC36 manual Operating Instructions