The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved fittings. When using black iron pipe always provide a union so the gas line can be easily disconnected for burner or fan servicing. (Fig. 7) Refer to gas specifica- tions for pressure details and ratings.
The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing.
1/2" Gas Supply
1/2" NPT x 1/2" Flare
3/8" Flex Line
(From Valve)
FP297a
Fig. 7 Typical gas supply installation.
Electrical Specifications
120V AC
60Hz
Less than 12 Amps
1/3 Horsepower