Vermont Casting RHEDV25 Large Lava Rock Placement, Flame Adjustment RN/RP Models, to decrease

Models: RHEDV25 RHEDV42 RHEDV32

1 38
Download 38 pages 58.07 Kb
Page 12
Image 12
Large Lava Rock Placement

Vermont Castings, Majestic Products RHEDV Direct Vent Insert

 

JR5

JR6

 

 

 

JR4

 

 

 

JR2

 

 

JR3

 

 

Burner Lava Rock

JR1

 

 

Placement

LG279

 

 

 

 

 

Fig. 18

RHEDV25 log and lava rock placement.

 

 

KR5

KR6

 

 

 

 

KR4

KR2

 

 

KR3

 

 

 

 

 

 

KR1

LG280

Burner Lava Rock

Placement

 

Fig. 19

RHEDV32 log and lava rock placement.

 

SR5

SR6

 

 

SR4

SR2

 

 

 

 

SR3

 

 

SR1

 

 

Front Lava Rock Placement

LG281

 

 

Fig. 20

RHEDV42 log and lava rock placement.

Large Lava Rock Placement

The large lava rock provided with this fireplace must be placed on the firebox base on either side of the burner assembly.

Under no circumstances should these lava rock be placed on top of the burner assembly.

Flame Adjustment (RN/RP Models)

For fireplaces equipped with HI/LO valves, flame adjustment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control. (Figs. 21 or 22)

Honeywell Valve

Turn

 

 

 

counterclockwise

LO

HI

Turn clockwise

to decrease

 

to increase

 

 

flame height

 

 

flame height

Fig. 21 Flame adjustment knob for Honeywell Valve.

 

SIT Valve

 

Turn

IH

Turn clockwise

counterclockwise

 

 

to decrease

to increase

 

 

flame height

flame height

LO

 

 

Fig. 22 Flame adjustment knob for SIT Valve.

Temperature Adjustment (TN/TP Models)

The HI/LO reference on the control knob (Fig. 23) is to indicate a higher or lower temperature setting. This setting controls the heat by reducing then shutting off the flame as the desired temperature is reached. Position the control knob where it effectively maintains a comfortable room temperature.

Fig. 23 Temperature adjustment knob for TN/TP models.

Flame Characteristics

It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the Figure 24 and Figure 25 or 26. If any of the flames appear abnormal call a service person.

12

10000801

Page 12
Image 12
Vermont Casting RHEDV25 Large Lava Rock Placement, Flame Adjustment RN/RP Models, Temperature Adjustment TN/TP Models