4.The chimney must be clean and in good working order and constructed of noncombustible materials.
5.Make sure that all chimney cleanouts fit properly so air cannot leak into the chimney.
6.Install the appliance without trim frame and make all gas fittings and electrical connections.
7.Install the decorative trim frame. Please refer to the Frame Assembly instructions.
Installer must attach red warning plate with screws supplied with the gas fire- place insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.
Cutting any sheet metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited.
Flue gas exits through the vent termination rain cap
Outside combustion air enters through the lower level of the vent termination
Secure with clamp and
three screws
1)Attach flexible pipe to rain cap
2)Secure with clamp
3)Attach raincap to
vent termination using three screws
Pull flexible pipe through vent termination
If the
WARNING
Some
Liner Installation - Fig. 9
The collar extending down from the termina- tion base is the air intake connector. Be sure the flex vent, which is connected to this collar, is also connected to the labelled air intake flue collar on the fireplace. Make sure the Flex vent is attached on the correct collar and cap for exhaust as well.
Slide the insulation provided in the termination kit over the two (2) 3" flex liners, (to be attached to the 3" Flue collar and cap of the termination). Feed one 3" flex vent from the bottom of the termination up through the 4" sleeve. Apply
NOTE
Minimum Vent Height -
12 feet
Maximum Vent Height -
35 feet
Air Intake
Air intake collar | Exhaust |
with label |
|
secured with | Exhaust collar secured |
clamp and three | |
screws | with clamp and three |
| screws |
FP1280
Fig. 9 Liner installation.
collar and attach intake flex vent in the same method. Feed the two flex liners down the chimney through the damper opening. Tighten termination to the chimney using the screws provided.
In case the fireplace opening is only minimum height 21" (533mm) and access from the front is not possible, then follow the instructions below.
1.Remove flue collar plate assembly. Unbolt the top fastener plate and move it to the back first before sliding the flue collar plate out from the top of the unit. (Fig. 10)
2.Apply a bead of
8 | 10000801 |