Download 38 pages 58.07 Kb
Page 8
Image 8
Liner Installation - Fig. 9

Vermont Castings, Majestic Products RHEDV Direct Vent Insert

4.The chimney must be clean and in good working order and constructed of noncombustible materials.

5.Make sure that all chimney cleanouts fit properly so air cannot leak into the chimney.

6.Install the appliance without trim frame and make all gas fittings and electrical connections.

7.Install the decorative trim frame. Please refer to the Frame Assembly instructions.

Installer must attach red warning plate with screws supplied with the gas fire- place insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.

Cutting any sheet metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited.

Flue gas exits through the vent termination rain cap

Outside combustion air enters through the lower level of the vent termination

Secure with clamp and

three screws

1)Attach flexible pipe to rain cap

2)Secure with clamp

3)Attach raincap to

vent termination using three screws

Pull flexible pipe through vent termination

If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch (37.5mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be p lugged with a noncombustible insulation after the gas supply line has been in- stalled.

WARNING

Some factory-built fireplaces have air passages on face of fireplace for zero clearance capabilities. All trim kits are designed so as to allow airflow to these passages. Under no circumstances should these passages be blocked.

Liner Installation - Fig. 9

The collar extending down from the termina- tion base is the air intake connector. Be sure the flex vent, which is connected to this collar, is also connected to the labelled air intake flue collar on the fireplace. Make sure the Flex vent is attached on the correct collar and cap for exhaust as well.

Slide the insulation provided in the termination kit over the two (2) 3" flex liners, (to be attached to the 3" Flue collar and cap of the termination). Feed one 3" flex vent from the bottom of the termination up through the 4" sleeve. Apply hi-temp sealant on the rain cap collar and slide the flex vent over the end of the rain cap collar fastening with the clamp provided. Slide the flex liner back down the 4" sleeve until 4" cap slides over the sleeve. Attach cap to the sleeve with four (4) screws supplied. Apply hi-temp sealant over the air intake

NOTE

Minimum Vent Height -

12 feet

Maximum Vent Height -

35 feet

Air Intake

Air intake collar

Exhaust

with label

 

secured with

Exhaust collar secured

clamp and three

screws

with clamp and three

 

screws

FP1280

Fig. 9 Liner installation.

collar and attach intake flex vent in the same method. Feed the two flex liners down the chimney through the damper opening. Tighten termination to the chimney using the screws provided.

In case the fireplace opening is only minimum height 21" (533mm) and access from the front is not possible, then follow the instructions below.

1.Remove flue collar plate assembly. Unbolt the top fastener plate and move it to the back first before sliding the flue collar plate out from the top of the unit. (Fig. 10)

2.Apply a bead of hi-temp sealant on the end of the collar before attaching the liner to the flue collar. Fasten it with two clamps then adjust fastener plate all the way to the back before sliding flue gas plate back onto the unit. (Fig. 11 and Fig. 12)

8

10000801

Page 8
Image 8
Vermont Casting RHEDV42, RHEDV25, RHEDV32 installation instructions Liner Installation - Fig, 10000801