Vermont Casting SDV30 Venting Requirements - Natural Vent Only, 20007065, 3’ .9 mm, 6’ 1.8 m

Models: SDV30

1 44
Download 44 pages 2.2 Kb
Page 11
Image 11
Inside Corner

Stardance Direct Vent/Natural Vent Gas Heater

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner

Outside Corner

Alcove Applications*

 

 

 

F =

 

 

G =

 

Combustible

G

Combustible

 

6"

(152 mm)

 

6" (152 mm)

V

Noncombustible

 

 

2"

(51 mm)

 

Noncombustible

 

V

 

F

 

2" (51 mm)

 

 

Balcony -

Balcony -

with no side wall

with perpendicular side wall

M

M

 

V

V

 

P

M =

Combustible &

Noncombustible

Combustible &

M = 24" (610 mm)

Noncombustible

P = 20” (508 mm)

12" (305 mm)

Outside CornerAlcove Applications* D Balcony -with no side wall

C C

V

3’ (.9 mm)6’ (1.8 m) E 9’ (2.7 m)

O

E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls

O = 8’ (2.4 m) Min.

No.

 

 

of Caps

DMin.

CMax.

1

3’ (.9 mm)

2 x DActual

2

6’ (1.8 m)

1 x DActual

3

9’ (2.7 m)
2/3 x DActual

4

12’ (3.7 m)
1/2 x DActual

DMin. = # of Termination caps x 3

CMax. = (2 / # termination caps) x DActual

584-15

*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.

Fig. 10 Termination clearances.

Venting Requirements - Natural Vent Only

(in feet)

unit before any elbow)

Vertical Run

from top of the

 

(Measured

��

��

�� 2/3 x DActualA

�� 12’ (3.7 m) B

��

��

��

��

��

��

��

��

��

��

������������������������������������������������������

Venting Runs

NOTE: When venting staight vertical, without any elbow, a minimum of 8 ft. vertical is required

off the top of the stove.

1/2 x DActual = Acceptable venting configuration Fig. 10 Termination clearances. = Unacceptable venting configuration

A:Vertical installations up to 36 feet (12m) in height. Up to an 18 ft. horizontal vent run can be installed within the vent system using a maximum of two 90-degree elbows or four 45-degree elbows.

B:Vertical installations up to 36 feet (12m) in height. Up to a 24 ft. horizontal vent run can be installed within the vent system using a maximum of two 45-degree elbows.

(Ratio = 2/3, Hor./Vert.)

Horizontal Run (in feet)

Fig. 11 Vent termination window - Natural Vent ONLY.

NOTE: When using the FSDHAG, the restrictor plate supplied with the stove is not used.

20007065