Stardance Direct Vent/Natural Vent Gas Heater

Fuel Conversion Instructions

WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions is not followed exactly, a fire, explosion

or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before pro- ceeding with the conversion.

 

 

OFF

 

 

I

N

 

 

H O

O

 

 

 

TPILOJAD

 

 

 

 

Main Gas

 

Gas Supply Inlet

Line

ST226

 

 

 

 

Fig. 52 Attach the gas line to the left side of the valve.

Conversion Precautions

Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.

Conversion Procedure

1.Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 33, Fig. 63)

2.Swing open the swiveling latches at the top left and right corners of the glass frame. (Page 34, Fig. 64)

3.Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a coun- ter protected by a towel.

4.Remove the logset from the firebox.

5.Remove the rear log bracket by unfastening the screw. (Fig. 53)

6.Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 53)

7.Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.

Remove Screws

Rear Log Bracket

Pilot

Left & Right Log

ST350

Bracket Assembly

 

Fig. 53 Remove the rear log bracket and left and right log bracket assembly.

8.Remove injector orifices from left burner leg using 1/2” wrench. (Fig. 60)

9.Install conversion orifices. (Refer to Table 2)

Models 3900, 3910 (R Models) Only Honeywell Valve

10.Remove cap from Hi-Lo knob. This can be accom- plished by lifting the plastic cap off the screw. (Fig. 54)

11.Remove the screw from center of Hi-Lo knob with small screwdriver turning counterclockwise. (Fig. 54)

Cap

HI

Lift Open

HI

 

LO

 

LO

Hi/Lo

 

 

Knob

Center Screw

CO100

 

 

Fig. 54 Remove center screw from Hi/Lo knob.

12.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.

13.Tighten screw (do not over tighten), replace cap.

SIT 820 Valve

14.Using TORX T20 bit, remove and discard the three

(3)pressure regulator mounting screws (A), pressure regulator tower (B) and the spring and diaphragm assembly (C). (Fig. 55)

15.Insure the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assem- bly to the valve using the new screws (E) supplied with the kit. Tighten the screws securely. (Ref. torque = 25 in/lb) (Fig. 56)

16.Install the enclosed conversion label (F) to the valve

body where it can easily be seen. (Fig. 57)

30

20007065

Page 30
Image 30