Venting System Assembly - Natural Vent

Stardance Direct Vent/Natural Vent Gas Heater

9.Install the storm collar and seal around the joints. (Fig. 31)

10.Add additional vent lengths to achieve the proper overall height.

11.Apply cement to the inner and outer termination col- lars and install the terminal cap.

#7DVAIS Attic Insulation Shield

Use Four

#7DVFS

8dNails

Firestop in

 

Upper Floor

 

#7DVFS

ST222

Firestop in

Ceiling

Fig. 30 Install firestops and attic insulation shield.

Use three #5 sheet

 

metal screws at

 

each joint

 

 

Sealant

Storm Collar

 

 

Upper

 

edge of

 

flange

 

goes under

 

upper

 

shingles

Flashing

 

#7DVSKV

 

(A, B, or F)

 

RoofSupport

ST221

Fig. 31 Roof support and flashing.

 

Venting System Assembly - Natural Vent

General Information

The Stardance Heater is shipped from the factory as a Direct Vent Heater. It may be converted to a Natural Vent heater by installing the Vermont Castings Model Z31D00 FSDHAG Draft Hood Adapter.

The Stardance Heater is approved for installation as a Natural Vent. CFM Direct Vent pipe could be used directly after the Draft Hood Adapter up to the ceiling, then B-vent pipe must be used. Do not mix types of B-vent pipe; use components from one maker or the other. Follow the vent component maker’s instructions exactly. The heater will also accept standard or enam- elled 7” (178mm) diameter pipe, around the Type B venting, for decorative purposes only. (Fig. 32)

NOTE: The restrictor plate supplied with the stove is not used for Natural Vent applications.

Decorative

CFM Direct Vent

System may be

7” Pipe

used after Draft

 

 

Hood up to the

4” B-vent

ceiling

Pipe

 

Draft Hood

 

Adapter

 

ST358

Fig. 32 Decorative 7” pipe may be fitted around the B-vent pipe.

The Stardance stove, when installed as a Natural vent heater, includes a vent safety switch. (Page 36, Figure

66)Operating the stove when it is not connected to a properly installed and maintained venting system, or tampering with or disconnecting the vent safety switch, can result in carbon monoxide (CO) poisoning and pos- sible death.

For U.S. installations: The venting system must con- form with local codes and/or the current National Fuel Gas Code, ANSI Z22.1.

For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.