Stardance Direct Vent/Natural Vent Gas Heater
Comfort Valve System Control Sequence of Operation with Transmitter
Set manual switch to local or remote
five minute wait period
Light pilot burner
Did the LED stop blinking?
Release pilotstat
knob
Review LED
failure analysis
Yes
Turn pilotstat knob from PILOT to ON
Local Path
Cycle switch once |
|
| Choose Manual or |
and leave in remote. |
|
| |
|
| Remote path. Set | |
Pressy any key on |
|
| |
|
| switch to manual or | |
transmitter for |
|
| |
|
| remote. | |
recognition operation |
|
| |
|
|
| |
| On Path |
If manual switch is set to LOCAL, did main burner light and fan turn on?
Yes
Turn pilotstat knob to PILOT to turn off main burner.
Turn pilotstat knob to OFF to turn valve completely off.
Move switch from local to remote. Press any key on transmitter. Move switch back to local.
If the manual switch is set to REMOTE, press the mode but- ton to display “ON”. Does transmitter con- trol the main burner and fan?
Yes
Does transmitter change levels of flame height, fan speed?
Set levels of flame height and fan to “0: to shut off main burner and fan.
Turn pilotstat knob to OFF to turn valve completely off.
No
Move switch from manual to remote. Press any key on transmitter.
28 | 20007065 |