Operation

Stardance Direct Vent/Natural Vent Gas Heater

Operation

The Stardance is operated with the operable door front plate in place with the doors open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the left and up. (Fig. 44) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud. (Fig. 47)

Clockwise

to Open

Counterclockwise

to Close

 

ST621

Fig. 44

To open the front doors, turn handle clockwise.

 

Handle

 

Holder

 

ST624

Fig. 45

When not in use, store handle in the handle holder.

ST476

Fig. 46 Pilot assembly location.

Flame & Temperature Adjustment

For stoves equipped with HI/LO valves, flame adjust- ment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 47)

Turn

 

 

 

counterclockwise

LO

HI

Turn clockwise

to decrease

 

to increase

 

 

flame height

 

 

flame height

Fig. 47 Flame adjustment knob for Honeywell valve.

Flame Characteristics

Your First Fire

Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly, Figure 46. Follow the lighting instructions on Page 24 exactly.

During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure

54.If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for as- sistance. Do not operate the heater until the pilot flame is correct.

Follow regular maintenance procedures as described on Page 33.

It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to Figure 48. If any of the flames appear abnormal, call a service person.

CO105c

Red Glow

LG143

Fig. 48 Correct pilot and burner flame patterns.

20007065

23