Outer

Slot

Shroud

 

 

Inner Shroud

 

Slot

ST194

 

Fig. 10 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws.

Left Air Duct

Snapstat

 

 

 

NOTE: Shown without

 

top for clarity.

ST671

 

 

Fig. 11 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is avail- able through the grille opening.

8.The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 12)

Remove retaining nut from shaft of rheostat. (if preinstalled)

Insert the rheostat through the hole in the back of the left side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.

Thread the retaining nut onto the shaft of the rheostat, tightening with a wrench. Do not over- tighten.

Attach the control knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat wire harnesses together.

9.Plug the power cord into a standard grounded 110 volt household outlet. If the fan control knob is not turned to the OFF position, the fan will turn on when the temperature at the snapstat reaches approxi- mately 109°F.

Retaining Nut

Control Knob

ST347a

Fig. 12 Attach rheostat to left side of valve.

Stardance Natural Vent Gas Heater

MOTOR

BLK

BLK

BLK

SNAPSTAT

 

 

 

BLK

 

WHT

WHT

GRN

ON/OFF

 

RHEOSTAT

 

POWER

ST196

Fig. 13 #2767 / FK26 fan wiring diagram.

Venting System Assembly

Adjust the leg levelers as needed. They should not extend any further from the leg than necessary.

The venting collar is on the sheet metal draft hood/heat exchanger assembly, over the firebox. Use a B-vent adapter, from the same maker as the rest of the B-vent components, to join the first section of venting to the draft hood.

The SNV30 stove includes a spill switch. Operating this stove when not connected to a properly installed and maintained venting system, or tampering with or discon- necting the spill switch, can result in carbon monoxide (CO) poisoning and possible death.

The stove includes a bracket for installing decorative 6” (152mm) round stove pipe around the B-vent, for ap- pearance purposes only. The decorative pipe need not be concentric with the vent pipe.

If the installation includes decorative stove pipe around the venting system, make a cardboard template of the decorative pipe by tracing its circumference. Put this template in the flue recess in the stove top. Position the template to fit well against the front of the recess. (Fig.

14)Use this template to locate the bracket to hold the decorative pipe. Depending on spacing, the bracket may fit inside the decorative pipe without interfering with the vent system. Fasten the bracket to the draft hood/heat exchanger assembly with a sheet metal screw.

Sheet Metal Screw

Template

Bracket

ST372

Fig. 14 Use a template to locate the bracket for decorative pipe to surround the B-vent pipe.

20007067

9

Page 9
Image 9
Vermont Casting SNV30 manual Venting System Assembly, Attach rheostat to left side of valve