3

Fig. 3.1

Screws

Screws

Terminal Block

Access Plate

Fig. 3.2

 

 

 

Ground strap

 

 

Neutral Wire

Terminal Block

 

 

B

Power Cord

 

Bracket

 

 

 

 

A

 

A: D=1” 9/64 (29 mm)

 

B: D=7/8” (22.5 mm)

 

 

Power Cord

Power Wires

Fig. 3.3

 

 

 

Cut Ground Strap

 

 

Neutral Wire

Terminal Block

B

Power Cord

 

Bracket

Grounding

 

 

 

 

 

Screw

 

A

 

A: D=1” 9/64 (29 mm)

 

B: D=7/8” (22.5 mm)

 

 

Power Wires

Grounding Wire

 

Power Cord

20

 

 

 

3-Wire Power Cord Installation (See Figure 3.2)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.1).

2.Check the correct positioning of the Power Cord Bracket as per figure 3.2.

3.Assemble the strain relief in the hole on Power Cord Bracket.

4.Insert the Power Cord through the strain relief and tighten.

5.Remove the 3 wire terminal nuts and washers from the Termi- nal Block.

6.Plug the terminal holes of Power Cord.

The Neutral or Ground Wire of the Power Cord must be con- nected to the neutral terminal located in the center of Terminal Block.

The Power Wires must be connected to the outside terminals.

7.Plug washers and tighten nuts securely.

 Do not remove Ground strap.

8.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.1).

4-Wire Power Cord Installation (See Figure 3.3)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.1).

2.Check the correct positioning of the Power Cord Bracket as per figure 3.3.

3.Assemble the strain relief in the hole on Power Cord Bracket.

4.Insert the Power Cord through the strain relief and tighten.

5.Remove the 3 wire terminal nuts and washers from the Termi- nal Block.

6.Remove the Ground Strap from the frame of range and termi- nal by removing its screw and cutting it as shown in Figure 3.3.

7.Plug the terminal holes of Power Cord.

The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using

the (Ground) identified Grounding Screw.

8.Plug washers and tighten nuts securely.

9.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.1).

Page 20
Image 20
Verona VEFSGE 304 SC manual Wire Power Cord Installation See Figure, =1 9/64 29 mm =7/8 22.5 mm Power Cord