2

CONVERSION TO LP/PROPANE GAS (OR CONVERSION BACK TO THE ORIGINAL GAS - NATURAL GAS)

Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced according to the “INJECTORS TABLE”.

The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

CAUTION: Save the orifices removed from the appliance for future use.

SETTING THE PRESSURE REGULATOR

The pressure regulator is accessible by opening the pivoting panel (fig. 2.6); the pressure regulator is positioned on the rear right side of the range (fig. 2.7).

To set the pressure regulator (fig. 2.7):

1.Unscrew the regulator cover.

2.Unscrew the “A” component, reverse and screw it according to the LP/PROPANE (or NATURAL GAS) regulation.

Fig. 2.6

Pressure regulator

Fig. 2.7

REGULATOR COVER

1 SETTING THE PRESSURE REGULATOR

To set the pressure regulator (fig. 2.7):NATURAL GAS 2

A

16

NATURAL GAS

LP/PROPANE

 

 