CONVERSION TO LP/PROPANE GAS (OR CONVERSION BACK TO THE ORIGINAL GAS - NATURAL GAS)
Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.
CAUTION: Save the orifices removed from the appliance for future use.
SETTING THE PRESSURE REGULATOR
The pressure regulator is accessible by opening the pivoting panel (fig. 2.6); the pressure regulator is positioned on the rear right side of the range (fig. 2.7).
To set the pressure regulator (fig. 2.7):
1.Unscrew the regulator cover.
2.Unscrew the “A” component, reverse and screw it according to the LP/PROPANE (or NATURAL GAS) regulation.
Fig. 2.6 |
Pressure regulator
Fig. 2.7
REGULATOR COVER
1
2
A
16 | NATURAL GAS | LP/PROPANE |
|
|