Verona VEFSGE 304 SC manual Wire Conduit Installation See Figure, fied Grounding Screw, Screws

Models: VEFSGE 304 SC

1 24
Download 24 pages 2.99 Kb
Page 21
Image 21
3-Wire Conduit Installation (See Figure 3.5)

3-Wire Conduit Installation (See Figure 3.5)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.4).

2.Check the correct positioning of the Conduit Bracket as per figure 3.5.

3.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the

Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

4.Plug the terminal holes of conductors.

The Neutral or Ground Wire must be connected to the neutral terminal located in the center of Terminal Block.

The Power Wires must be connected to the outside terminals.

5.Plug washers and tighten nuts securely.

4-Wire Conduit Installation (See Figure 3.6) Do not remove Ground strap.

6.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.4).

4-Wire Conduit Installation (See Figure 3.6)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.4).

2.Check the correct positioning of the Conduit Bracket as per figure 3.6.

3.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the

Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

4.Remove the 3 wire terminal nuts and washers from the Termi- nal Block.

5.Remove the Ground Strap from the frame of range and termi- nal by removing its screw and cutting it as shown in Figure 3.6.

6.Plug the terminal holes of conductors.

The Neutral Wire must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identi-

fied fied  Grounding Screw. Grounding Screw.

3

Fig. 3.4

Screws

Screws

Terminal Block

Access Plate

Fig. 3.5

 

 

 

Ground strap

 

Neutral Wire

Terminal Block

A

Power Cord

 

Bracket

 

 

 

 

B

 

A: D=1” 9/64 (29 mm)

 

B: D=7/8” (22.5 mm)

 

 

Conduit Clamp

Power Wires

 

Conduit

 

 

Fig. 3.6

Cut Ground Strap

7.Plug washers and tighten nuts securely.

8.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.4).

Neutral Wire

APower Cord

Terminal BlockConduit Clamp Bracket

ConduitManual background B

A: D=1” 9/64 (29 mm)

B: D=7/8” (22.5 mm)

Terminal Block

Grounding

Screw

Power Wires

 

Grounding Wire

 

 

 

Conduit

Conduit Clamp

 

 

 

 

21

 

 

 

 

 

 

 

 

Page 21
Image 21