VerteX RTH Series H.8 and H.16 Series
65
[Figure 5- . Firmware Upgrade Progressing Window]
Downgrading to a previous version is not supported.
It is recommended that the DVR ID should be the same as the remote controller ID.
The upgrade information window will then appear within 15 seconds.
 Read the information and select {Yes} to start the upgrade gradually. Select {No} to return to {System}
mode.
 After the update is completed, the system will be rebooted.
 The system will automatically start. Upgrade is then completed.
 Move to {Status} Æ {Product Information} Æ {Software Version} to check the version.
All setup data are a fixed value in {Menu}Æ{Setup}Æ{System}Æ{6.
Upgrade}Æ{Setup}
6-7-8. Factory Setup
 Move to {Menu} Æ {Setup} Æ {System} Æ {7. Factory Setup}.
 Select {Yes} when Initialization (Yes/No) Window appears.
Note that all setting data will be initialized it goes back to Factory Default Value.
6-7-9. RS232C Port
 Move to {Menu} Æ {Setup} Æ {System} Æ {8. RS232C Port}.
 On the selection window, select the device using the arrow keys and the Select button.
6-7-10. Error Alarm Action
Alarm is to notify occurrences such as events [Sensor, Motion and Audio] and system incidents [Video Signal
disconnected/ HDD full/ FAN fail/ HDD fail/ HDD warning] to [Alarm/ E-mail/ Relay01/ System check].
 Move to {Menu} Æ {Setup} Æ {System} Æ {9. Error Alarm Action}.
 Select [Alarm/E-mail/Relay01/System Check]. The user can select all by ticking as shown below.
[Figure 5- Error Alarm Action]
System Check
System Check is to pop up the System Check Window on the monitoring screen. It indicates [Buzzer /