Installation

Vidikron PlasmaView VHD Installation/Operation Manual 23

PRELIMINARY
RS-232 Connection: Connect the RS-232 output from the VHD Controller to the SERIAL input on the PlasmaView VHD. Use a standard, modular telephone cable with RJ11 plugs at both ends. On the PlasmaView VHD end, use the provided RJ11-to-DB9 adapter. This adapter is wired as shown in Figure 3-5. Figure 3-5. RS-232 Connection from the VHD Controller to the PlasmaView VHD
3
4
2, 5
XMT DATA RCV DATA
REQUEST TO SEND
SIG GND
3
2
8
7
5
RCV DATA XMT DATA
CLEAR TO SEND
NO CONNECTION
1, 6 1, 9
SIG GND
To/From
VHD
Controller
PlasmaView
RJ-11 Male
DB-9 Female
1 5
6 9

SERIAL