Regarding the indicator lamps

Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the table below. Please respond in accordance with the instructions within the table. If the same indication is displayed after the treatment, or if an indication other than the following is displayed, please contact your dealer or service company.

POWER

LAMP

TEMP

 

Description

indicator

indicator

indicator

 

 

 

Lighting

Turned

Turned

The projector is in a standby state.

in

off

off

Please refer to the section “Power On/Off”. ( 16)

Orange

 

 

 

 

Blinking

Turned

Turned

The projector is warming up.

in Green

off

off

Please wait.

Lighting

Turned

Turned

The projector is in an on state.

in Green

off

off

Ordinary operations may be performed.

Blinking

Turned

Turned

The projector is cooling down.

in

off

off

Please wait.

Orange

 

 

 

 

Blinking

(discre-

(discre-

The projector is cooling down. A certain error

in Red

tionary)

tionary)

has been detected.

 

 

 

Please wait until the POWER indicator finishes

 

 

 

blink, and then perform the proper response

 

 

 

measure using the item descriptions below as

 

 

 

reference.

Blinking

Lighting

Turned

The lamp does not light, and there is a possibility

in Red

in Red

off

that interior portion has become heated.

or

 

 

Please turn the power off, and allow the unit to cool

Lighting

 

 

down at least 20 minutes. After the projector has

in Red

 

 

sufficiently cooled down, please make confirmation of

 

 

 

the following items, and then turn the power on again.

 

 

 

Is there blockage of the air passage aperture?

 

 

 

Is the air filter dirty?

 

 

 

Does the peripheral temperature exceed 35°C?

 

 

 

If the same indication is displayed after the

 

 

 

treatment, please change the lamp by referring to

 

 

 

the section “Lamp”. ( 41)

Blinking

Blinking

Turned

The lamp cover has not been properly fixed

in Red

in Red

off

(attached).

or

 

 

Please turn the power off, and allow the unit to cool

Lighting

 

 

down at least 45 minutes. After the projector has

in Red

 

 

sufficiently cooled down, please make confirmation of

 

 

 

the attachment state of the lamp cover. After performing

 

 

 

any needed maintenance, turn the power on again. If the

 

 

 

same indication is displayed after the treatment, please

 

 

 

contact your dealer or service company.

ViewSonic PJ452

48

Page 52
Image 52
ViewSonic PJ452 manual Regarding the indicator lamps