Sprinkler 11f | March 7, 2008 |
MICROMATIC® AND
TECHNICAL DATA MicromaticHP® STANDARD
RESPONSE PENDENT
SPRINKLERS
The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058
Telephone:
Approval Chart 3
MicromaticHP® Standard Response Pendent Sprinklers
Maximum 250 PSI (17 bar) WWP
Sprinkler |
| Thread Size | Nominal | Overall |
|
|
| Listings and Approvals3 |
|
| ||||||||||||
Base Part | SIN | Length |
| (Refer also to Design Criteria on page 11g.) |
| |||||||||||||||||
|
|
|
| |||||||||||||||||||
| Number1 |
| NPT | BSP | U.S. | metric2 | Inches |
| mm | cULus4 |
| FM |
| NYC |
| VdS |
| LPCB |
|
|
| |
|
|
|
|
|
|
| Standard Orifice |
|
|
|
|
|
|
|
|
|
|
| ||||
| 09992 | VK122 | 1/2” | 15 mm | 5.6 | 80.6 |
| 58 | A1, D2 |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Small Orifice7 |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 099947,8 | VK023 | 1/2” | 15 mm | 2.8 | 40.3 |
| 58 | A1 |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| Installed with the Viking Micromatic® Model |
|
|
|
|
|
| ||||||||||||
| 09992 | VK122 | 1/2” | 15 mm | 5.6 | 80.6 |
| 58 | C1 |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 099947,8 | VK023 | 1/2” | 15 mm | 2.8 | 40.3 |
| 58 | C1 |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| Installed with the Viking Microfast® Model |
|
|
|
|
|
| ||||||||||||
| 09992 | VK122 | 1/2” | 15 mm | 5.6 | 80.6 |
| 58 | B1 |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 099947,8 | VK023 | 1/2” | 15 mm | 2.8 | 40.3 |
| 58 | B1 |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Approved Temperature Ratings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F |
|
|
| Approved Finishes |
|
|
|
| ||||||||||||||
| (141 °C), and 360 °F (182 °C) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
| 1 - Brass, | ||||||||||||||||
B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F | ||||||||||||||||||||||
Black Teflon®5 |
|
|
|
|
|
|
|
|
| |||||||||||||
| (141 °C) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| 2 - Brass and |
|
|
|
|
|
| |||||||
C - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) |
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
D - 500 °F (260 °C)8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| Footnotes |
|
|
|
|
|
|
|
|
|
|
| |||
1 | Base part number is shown. For complete part number, refer to Viking’s current price schedule. |
|
|
|
|
|
|
|
|
| ||||||||||||
2 | Metric | |||||||||||||||||||||
3 | This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. |
|
| |||||||||||||||||||
4 | Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
5 | cULus Listed as corrosion resistant. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
6 | Other colors are available on request with the same Listings and Approvals as the standard colors. |
|
|
|
|
|
| |||||||||||||||
7 | Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated | |||||||||||||||||||||
| wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or | |||||||||||||||||||||
| internally galvanized. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
8 | The sprinkler orifice is bushed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
9 | Sprinklers of | |||||||||||||||||||||
| 300 °F (149 °C). Where the ambient temperature around the | |||||||||||||||||||||
| the response time of the |
|
|
|
|
|
|
|
|
|