preset_i<0~127>_name string[40] 1/4 Name of the preset location.
preset_i<0~127>_
dwelling
0 ~ 255 1/4 Dwelling time at each preset location.
patrol_i<0~39>_name string[40] 1/4 The name of patrol location
patrol_i<0~39>_
dwelling
0 ~ 255 1/4 The dwelling time of each patrol location
returnhome <boolean> 6/6 Enable/disable auto return home while idle
returnhomeinterval <integer> 6/6 Wait interval return home
defaulthome <boolean> 6/6 This field tells system to use default home
position or not.
digitalzoom <boolean> 6/6 Enable/disable digital zoom
disablemdonptz <boolean> 1/4 Disabl e motion detection on PTZ operation.
Group:uart_i<0~(n-1)> n is uart port count (capability.nuart>0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,120
0,2400,3600,480
0,7200,9600,192
00,38400,57600,
115200
4/4 Set baud rate of COM port.
databit 5,6,7,8 4/4 Data bits in a character frame.
paritybit none,
odd,
even
4/4 For error checking.
stopbit 1,2 4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485,
rs232
4/4 RS485 or RS232.
Group: layout (product dependent) (FD7132, FD7151)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
logo_default <boolean> 1/6 0 => Custom logo
1 => Default logo
logo_link string[40] 1/6 Hyperlink of the logo
logo_powerbyvvtk_hidden <boolean> 1/6 0 => display the power by vivotek logo
1 => hide the power by vivotek logo