preset_i<0~127>_name

string[40]

1/4

Name of the preset location.

 

 

 

 

preset_i<0~127>_

0 ~ 255

1/4

Dwelling time at each preset location.

dwelling

 

 

 

 

 

 

 

patrol_i<0~39>_name

string[40]

1/4

The name of patrol location

 

 

 

 

patrol_i<0~39>_

0 ~ 255

1/4

The dwelling time of each patrol location

dwelling

 

 

 

 

 

 

 

returnhome

<boolean>

6/6

Enable/disable auto return home while idle

 

 

 

 

returnhomeinterval

<integer>

6/6

Wait interval return home

 

 

 

 

defaulthome

<boolean>

6/6

This field tells system to use default home

 

 

 

position or not.

 

 

 

 

digitalzoom

<boolean>

6/6

Enable/disable digital zoom

 

 

 

 

disablemdonptz

<boolean>

1/4

Disable motion detection on PTZ operation.

 

 

 

 

Group:uart_i<0~(n-1)>n is uart port count (capability.nuart>0)

 

NAME

 

 

VALUE

 

 

 

SECURITY

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

baudrate

 

110,300,600,120

 

4/4

 

 

 

 

Set baud rate of COM port.

 

 

 

 

0,2400,3600,480

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0,7200,9600,192

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00,38400,57600,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

databit

 

5,6,7,8

 

 

 

 

4/4

 

 

 

 

Data bits in a character frame.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

paritybit

 

 

none,

 

 

4/4

 

 

 

 

For error checking.

 

 

 

 

 

odd,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

even

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stopbit

 

1,2

 

 

 

 

4/4

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1.5 , data bit is 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

uartmode

 

rs485,

 

 

4/4

 

 

 

 

RS485 or RS232.

 

 

 

 

 

rs232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group: layout (product dependent) (FD7132, FD7151)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NAME

 

 

 

 

 

VALUE

 

 

 

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

logo_default

 

 

 

 

 

<boolean>

 

1/6

 

 

 

 

 

 

0 => Custom logo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 => Default logo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

logo_link

 

 

 

 

 

string[40]

 

1/6

 

 

 

 

 

 

Hyperlink of the logo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

logo_powerbyvvtk_hidden

 

<boolean>

 

1/6

 

 

 

 

 

 

0 => display the power by vivotek logo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 => hide the power by vivotek logo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User's Manual - 123