Status LEDs

Each time VisualServer starts, it will perform a Power-On Self Test, abbreviated as POST hereafter, to examine every hardware module. As soon as the administrator plugs in the power adapter, both LEDs under the network LED will flash one by one until the POST is done. If any module fails, both LEDs will indicate to the users the error according to the pattern listed in Appendix A. If the result is good, both LEDs will turn off for a while and then follows the pattern below. Network interface depends on the peripherals including Ethernet UTP cable, modem or null modem cable. If the Ethernet cable between VisualServer and Ethernet hub is good, VisualServer will choose the Ethernet network. If Ethernet is unavailable but a operational modem is connected, the network interface will be PPP with modem. If either of the above is not the case, VisualServer will try the interface of PPP with null modem.

Network Interface

Condition

LED2 (Heartbeat)

LED3 (Status)

 

 

 

 

Ethernet

before installed

OFF

OFF

 

 

 

 

 

after installed

flash

OFF

 

 

 

 

 

during camera control

flash

Flash

 

 

 

 

PPP with modem

after POST

flash

ON

 

 

 

 

PPP with null modem

before connected

ON

ON

 

 

 

 

 

after connected

flash

ON

 

 

 

 

11

www.vivotek.com

T: 886-2-22404099

F: 886-2-22404097

Page 12
Image 12