FILTER VALVE AND DISCARD

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS

21.Reverse procedure to install all the parts removed from original fry tank onto replacement fry tank, then install the assembly.

FILTER VALVE AND DISCARD

VALVE SWITCHES

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Open the door to the fryer section being serviced.

2.Remove burners (as necessary) as outlined under MAIN BURNERS.

3.Disconnect lead wire connector (2 pin) from the appropriate switch.

4.Remove switch mounting screws.

NOTE: The remaining steps are written for front removal of the pump assembly. If access to the back of the fryer is available, it may be easier to remove the pump from the rear.

3.Remove burners from the right side fryer section above filter tank drawer as outlined under MAIN BURNERS.

4.Disconnect the electrical connection to the motor.

5.Separate the swivel hose connections at the pump.

NOTE: When viewed from pump end, the right side is the intake port and the left side is the discharge port.

6.Remove motor mounting bolts.

7.Remove the motor and pump (pipe fittings attached) from the fryer.

A.If replacing the pump and motor, remove the existing pipe assemblies and reuse.

8.Reverse procedure to install.

NOTE: Ensure the rubber vibration pad or the grommets are installed under the motor mounting plate.

5.Reverse procedure to install and check for proper operation.

NOTE: Switches are not adjustable.

PUMP AND MOTOR

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Open both fryer cabinet doors above the filter tank drawer.

2.Pull the filter drawer out, remove the filter tank assembly and push the tank support arms back underneath the fryer.