Vulcan-Hart GR25, GR85F, GR65F, GR35F, GR45F Control Thermostat, High Limit Thermostat

Models: GR85 GR35 GR25 GR45F GR35F GR65F GR85F GR65 GR45

1 24
Download 24 pages 44.48 Kb
Page 6
Image 6
CONTROL THERMOSTAT

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS

2.When replacing door, install screws and tighten top and bottom screws enough to hold door in place.

3.Close door, check alignment and adjust if necessary.

4.Finish tightening screws to fully secure.

CONTROL THERMOSTAT

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

CAUTION: Do not sharply bend and kink the capillary tube or damage may occur.

1.Drain shortening from fry tank.

2.Remove burners (as necessary) as outlined under MAIN BURNERS.

3.Remove knob from control thermostat shaft then remove control thermostat from mounting bracket.

NON FILTER READY SHOWN

4.Disconnect lead wires from control thermostat.

5.Remove the capillary tube retaining and packing nuts, from the bottom of fry tank.

6.Remove screws securing capillary tube mounting clips to the fry tank heat tube then remove capillary tube.

7.Reverse procedure to install and check for proper operation.

HIGH LIMIT THERMOSTAT

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

CAUTION: Do not sharply bend and kink the capillary tube or damage may occur.

1.Drain shortening from fry tank.

2.Remove burners (as necessary) as outlined under MAIN BURNERS.

3.Remove screws securing the high limit thermostat to mounting bracket.

4.Disconnect lead wires from high limit thermostat.

F25125 (March 2003)

 

Page 6 of 24

 

Page 6
Image 6
Vulcan-Hart GR25, GR85F, GR65F, GR35F, GR45F service manual Control Thermostat, High Limit Thermostat