GR SERIES GAS FRYERS - ELECTRICAL OPERATION
ELECTRICAL OPERATION
COMPONENT FUNCTION
| FRYER CONTROLS |
Control Thermostat | Regulates shortening temperature at the selected set point. Temperature |
| range from off to 200/F thru 400/F. |
Thermopile | When heated by the pilot burner flame, generates DC millivolts to |
| energize pilot valve coil and main valve coil on the gas combination valve. |
Gas Combination |
|
Valve | Allows gas flow to the pilot when pilot valve coil is energized; and gas flow |
| to the main burners when main valve coil is energized. Also, regulates the |
| gas manifold pressure. |
High Limit Thermostat | Prevents the shortening from reaching temperatures over 465°F (auto |
| reset). |
| KLEENSCREEN FILTER CONTROLS |
Filter Power Switch | . . Supplies 120VAC to pump motor. Filter valve switch or discard valve |
| switch must be closed (valve handle extended). |
Pump Motor | . . Operates pump to circulate shortening through filtering system. |
Filter Valve Switch | . . Energizes pump motor to filter the shortening when the N.O. switch |
| contacts are closed (valve handle extended); and filter power switch is |
| turned on. |
Discard Valve Switch | . . Energizes pump motor to discard the shortening from filter tank when the |
| N.O. switch contacts are closed (valve handle extended); and filter power |
| switch is turned on. |
Page 15 of 24 |