GR SERIES GAS FRYERS - TROUBLESHOOTING
TROUBLESHOOTING
ALL MODELS
SYMPTOMS |
| POSSIBLE CAUSES |
Pilot burner will not light. | 1. | Gas supply off. |
| 2. | High limit thermostat open or malfunction. |
| 3. | Incorrect gas type. |
| 4. | Pilot burner flame adjustment too low. |
| 5. | Pilot burner orifice obstructed or incorrect. |
| 6. Gas combination valve malfunction. | |
|
|
|
Pilot burner lights but will not maintain flame. | 1. | Pilot burner flame adjustment too low. |
| 2. | Pilot burner orifice obstructed or incorrect. |
| 3. | Thermopile malfunction. |
| 4. | Insufficient gas pressure. |
| 5. | High limit thermostat malfunction. |
| 6. | Gas combination valve malfunction. |
|
|
|
Pilot burner adjusted properly but flame | 1. | Insufficient gas pressure due to other equipment |
fluctuates or goes out. |
| operating on same line. |
| 2. | Excessive drafts. |
|
| A. Vent hood not adjusted properly. |
|
| B. Fryer door open or removed. |
|
|
|
Main burner(s) light but will not maintain | 1. | Insufficient gas pressure. |
flame. | 2. | Main burner(s) gas orifice obstructed or incorrect. |
| 3. | Thermopile malfunction |
| 4. | Main burner(s) malfunction. |
| 5. Gas combination valve malfunction. | |
|
|
|
Fryer does not heat, pilot burner lit. | 1. | Control thermostat off or malfunctioning. |
| 2. Gas combination valve malfunction. | |
| 3. | Wiring connections loose or wiring malfunction. |
|
|
|
Excessive or low heat. | 1. | Control thermostat calibration or malfunction. |
| 2. | Gas pressure incorrect. |
| 3. | Main burner(s) gas orifice obstructed or incorrect. |
| 4. | Flue obstructed. |
| 5. | Vent hood not adjusted properly. |
| 6. | Fryer load capacity exceeded. |
|
|
|
High limit thermostat shutting off main | 1. | Shortening level below minimum fill line. |
burners. | 2. | Control thermostat malfunction. |
| 3. | High limit thermostat malfunction. |
|
|
|
Main burners light when control thermostat is | 1. | Control thermostat malfunction. |
turned off. | 2. | Control thermostat terminals shorted or lead wire |
|
| grounded. |
| 3. | Gas combination valve malfunction. |
F25125 (March 2003) |
| Page 22 of 24 |
|