Vulcan-Hart GR35F, GR45, GR85F, GR65F Troubleshooting, All Models, Symptoms, Possible Causes

Models: GR85 GR35 GR25 GR45F GR35F GR65F GR85F GR65 GR45

1 24
Download 24 pages 44.48 Kb
Page 22
Image 22
TROUBLESHOOTING

GR SERIES GAS FRYERS - TROUBLESHOOTING

TROUBLESHOOTING

ALL MODELS

SYMPTOMS

 

POSSIBLE CAUSES

Pilot burner will not light.

1.

Gas supply off.

 

2.

High limit thermostat open or malfunction.

 

3.

Incorrect gas type.

 

4.

Pilot burner flame adjustment too low.

 

5.

Pilot burner orifice obstructed or incorrect.

 

6. Gas combination valve malfunction.

 

 

 

Pilot burner lights but will not maintain flame.

1.

Pilot burner flame adjustment too low.

 

2.

Pilot burner orifice obstructed or incorrect.

 

3.

Thermopile malfunction.

 

4.

Insufficient gas pressure.

 

5.

High limit thermostat malfunction.

 

6.

Gas combination valve malfunction.

 

 

 

Pilot burner adjusted properly but flame

1.

Insufficient gas pressure due to other equipment

fluctuates or goes out.

 

operating on same line.

 

2.

Excessive drafts.

 

 

A. Vent hood not adjusted properly.

 

 

B. Fryer door open or removed.

 

 

 

Main burner(s) light but will not maintain

1.

Insufficient gas pressure.

flame.

2.

Main burner(s) gas orifice obstructed or incorrect.

 

3.

Thermopile malfunction

 

4.

Main burner(s) malfunction.

 

5. Gas combination valve malfunction.

 

 

 

Fryer does not heat, pilot burner lit.

1.

Control thermostat off or malfunctioning.

 

2. Gas combination valve malfunction.

 

3.

Wiring connections loose or wiring malfunction.

 

 

 

Excessive or low heat.

1.

Control thermostat calibration or malfunction.

 

2.

Gas pressure incorrect.

 

3.

Main burner(s) gas orifice obstructed or incorrect.

 

4.

Flue obstructed.

 

5.

Vent hood not adjusted properly.

 

6.

Fryer load capacity exceeded.

 

 

 

High limit thermostat shutting off main

1.

Shortening level below minimum fill line.

burners.

2.

Control thermostat malfunction.

 

3.

High limit thermostat malfunction.

 

 

 

Main burners light when control thermostat is

1.

Control thermostat malfunction.

turned off.

2.

Control thermostat terminals shorted or lead wire

 

 

grounded.

 

3.

Gas combination valve malfunction.

F25125 (March 2003)

 

Page 22 of 24

 

Page 22
Image 22
Vulcan-Hart GR35F, GR85F, GR65F, GR45F, GR25 service manual Troubleshooting, All Models, Symptoms, Possible Causes