GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
SPECIFICATIONS
Electrical
•120VAC supply for
Gas Pressures
Manifold (per fryer section):
•Natural - 4" W.C.
•Propane - 10" W.C. Building supply pressure (Min):
•Natural - 5" W.C. (7" W.C. battery units)
•Propane - 11" W.C. (12" W.C. battery units) NOTE: Propane or Natural gases
Input BTU Rating
GR SERIES | NO. OF | BTU/HR/SECTION |
| TUBES |
|
GR25, GR25F | 2 | 60,000 |
|
|
|
GR35, GR35F | 3 | 90,000 |
|
|
|
GR45, GR45F | 4 | 120,000 |
|
|
|
GR65, GR65F | 5 | 150,000 |
|
|
|
GR85, GR85F | 5 | 150,000 |
|
|
|
TOOLS
Standard
•Standard set of hand tools.
•VOM with AC current tester.
NOTE: Any quality VOM with a sensitivity of 20,000 ohms per volt can be used.
•Temperature tester (thermocouple type).
•
•Pipe joint compound suitable for use with propane gas.
REMOVAL AND REPLACEMENT OF PARTS
FRONT PANEL |
| DOOR |
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.Open fryer door and remove screws from front panel.
1.Open the fryer door and remove screws securing hinge & door assembly to fryer.
2.Lift front panel from fryer.
3.Reverse procedure to install.
Page 5 of 24 |