SPECIFICATIONS

Electrical

120VAC supply for Filter-Ready fryers and Kleenscreen filter models only. The filter pump motor draws approximately 5 amps.

Gas Pressures

Manifold (per fryer section):

Natural - 4" W.C.

Propane - 10" W.C. Building supply pressure (Min):

Natural - 5" W.C. (7" W.C. battery units)

Propane - 11" W.C. (12" W.C. battery units) NOTE: Propane or Natural gases -14" W.C. (Max).

Input BTU Rating

GR SERIES

NO. OF

BTU/HR/SECTION

 

TUBES

 

GR25, GR25F

2

60,000

 

 

 

GR35, GR35F

3

90,000

 

 

 

GR45, GR45F

4

120,000

 

 

 

GR65, GR65F

5

150,000

 

 

 

GR85, GR85F

5

150,000

 

 

 

TOOLS

Standard

Standard set of hand tools.

VOM with AC current tester.

NOTE: Any quality VOM with a sensitivity of 20,000 ohms per volt can be used.

Temperature tester (thermocouple type).

U-Tube Manometer.

Pipe joint compound suitable for use with propane gas.

REMOVAL AND REPLACEMENT OF PARTS

FRONT PANEL

 

DOOR

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Open fryer door and remove screws from front panel.

1.Open the fryer door and remove screws securing hinge & door assembly to fryer.

2.Lift front panel from fryer.

3.Reverse procedure to install.